Evaluation of a retinal oximetry image quality indicator in patients with cataract

Oliver Niels Klefter iD, Jesper Høiberg Erichsen, Mathias Møller Hansen iD, Lars Morten Holm, Sveinn Hakon Hardarson, Einar Stefánsson iD, Line Kessel iD

Acta Ophthalmologica · 2024

DOI: 10.1111/aos.15747 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Ophthalmologica, 2024. Verfasst von Oliver Niels Klefter und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Rigshospitalet Glostrup, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Quality Indicators, Health Care, Cataract. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: Fight for Sight Denmark, Henry and Astrid Møllers Fond, The Danish Council for Independent Research (Det Frie Forskningsråd, Sundhed og Sygdom).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate a new automated retinal oximetry image quality indicator with cataract as a clinical model.

Methods

Sixty‐one eyes in 61 patients were imaged by the Oxymap T1 Retinal Oximeter at baseline and 25 eyes were also examined 3 weeks after cataract surgery. Image quality (0–10 on a continuous scale) was compared with standardized AREDS cataract grading and Pentacam lens densitometry. Associations with retinal oximetry measurements and visual acuity were examined.

Results

Image quality correlated with total, nuclear and posterior subcapsular cataract grades (ANOVA, p < 0.05), tended to be associated with lens densitometry and it improved from 4.3 ± 1.4 to 5.7 ± 1.0 ( p < 0.05) after cataract surgery. Very low image quality, below 3, led to vessel detection failure in retinal oximetry images. Higher image qualities were linearly associated with higher measured retinal oxygen saturations ( r = 0.52 in arteries and r = 0.46 in veins; p < 0.001).

Conclusion

Retinal oximetry image quality deteriorated with increasing cataract density and improved after cataract surgery, supporting its use as a measure of optical clarity. The numerical quality indicator demonstrated a threshold below which images of poor optical quality should be discarded. Image quality affects the estimates of retinal oximetry parameters and should therefore be included in future analyses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quality Indicators, Health CareCataractHumansRetinal VesselsOximetryOxygen

Stichwörter der Autor:innen

cataractimage qualityretinaretinal imagingretinal oximetry

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Ophthalmology, Rigshospitalet Glostrup, Copenhagen, Denmark.
  • Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
  • Department of Medicine, University of Iceland, Reykjavik, Iceland.
  • Department of Ophthalmology, Landspitali, Reykjavik, Iceland.

ORCID-Profile: Oliver Niels Klefter, Mathias Møller Hansen, Einar Stefánsson, Line Kessel

Förderung

  • Fight for Sight Denmark
  • Henry and Astrid Møllers Fond
  • The Danish Council for Independent Research (Det Frie Forskningsråd, Sundhed og Sygdom)
  • The Rigshospitalet Research Foundation (Rigshospitalets Forskningspulje)

Zitieren

APA

Klefter, O. N., Erichsen, J. H., Hansen, M. M., Holm, L. M., Hardarson, S. H., Stefánsson, E., & Kessel, L. (2024). Evaluation of a retinal oximetry image quality indicator in patients with cataract. Acta Ophthalmologica. https://doi.org/10.1111/aos.15747

Vancouver

Klefter ON, Erichsen JH, Hansen MM, Holm LM, Hardarson SH, Stefánsson E, et al. Evaluation of a retinal oximetry image quality indicator in patients with cataract. Acta Ophthalmologica. 2024. doi:10.1111/aos.15747

BibTeX
@article{Klefter2024,
  author = {Klefter, Oliver Niels and Erichsen, Jesper Høiberg and Hansen, Mathias Møller and Holm, Lars Morten and Hardarson, Sveinn Hakon and Stefánsson, Einar and Kessel, Line},
  title = {Evaluation of a retinal oximetry image quality indicator in patients with cataract},
  journal = {Acta Ophthalmologica},
  year = {2024},
  doi = {10.1111/aos.15747}
}
Kostenlos starten →