Evaluation of a retinal oximetry image quality indicator in patients with cataract
Acta Ophthalmologica · 2024
DOI: 10.1111/aos.15747 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Ophthalmologica, 2024. Verfasst von Oliver Niels Klefter und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Rigshospitalet Glostrup, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Quality Indicators, Health Care, Cataract. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: Fight for Sight Denmark, Henry and Astrid Møllers Fond, The Danish Council for Independent Research (Det Frie Forskningsråd, Sundhed og Sygdom).
Abstract (Originalsprache)
Purpose
To evaluate a new automated retinal oximetry image quality indicator with cataract as a clinical model.
Methods
Sixty‐one eyes in 61 patients were imaged by the Oxymap T1 Retinal Oximeter at baseline and 25 eyes were also examined 3 weeks after cataract surgery. Image quality (0–10 on a continuous scale) was compared with standardized AREDS cataract grading and Pentacam lens densitometry. Associations with retinal oximetry measurements and visual acuity were examined.
Results
Image quality correlated with total, nuclear and posterior subcapsular cataract grades (ANOVA, p < 0.05), tended to be associated with lens densitometry and it improved from 4.3 ± 1.4 to 5.7 ± 1.0 ( p < 0.05) after cataract surgery. Very low image quality, below 3, led to vessel detection failure in retinal oximetry images. Higher image qualities were linearly associated with higher measured retinal oxygen saturations ( r = 0.52 in arteries and r = 0.46 in veins; p < 0.001).
Conclusion
Retinal oximetry image quality deteriorated with increasing cataract density and improved after cataract surgery, supporting its use as a measure of optical clarity. The numerical quality indicator demonstrated a threshold below which images of poor optical quality should be discarded. Image quality affects the estimates of retinal oximetry parameters and should therefore be included in future analyses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, Rigshospitalet Glostrup, Copenhagen, Denmark.
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
- Department of Medicine, University of Iceland, Reykjavik, Iceland.
- Department of Ophthalmology, Landspitali, Reykjavik, Iceland.
ORCID-Profile: Oliver Niels Klefter, Mathias Møller Hansen, Einar Stefánsson, Line Kessel
Förderung
- Fight for Sight Denmark
- Henry and Astrid Møllers Fond
- The Danish Council for Independent Research (Det Frie Forskningsråd, Sundhed og Sygdom)
- The Rigshospitalet Research Foundation (Rigshospitalets Forskningspulje)
Zitieren
APA
Klefter, O. N., Erichsen, J. H., Hansen, M. M., Holm, L. M., Hardarson, S. H., Stefánsson, E., & Kessel, L. (2024). Evaluation of a retinal oximetry image quality indicator in patients with cataract. Acta Ophthalmologica. https://doi.org/10.1111/aos.15747
Vancouver
Klefter ON, Erichsen JH, Hansen MM, Holm LM, Hardarson SH, Stefánsson E, et al. Evaluation of a retinal oximetry image quality indicator in patients with cataract. Acta Ophthalmologica. 2024. doi:10.1111/aos.15747