Impact of uncertainties in biometric parameters on intraocular lens power formula predicted refraction using a Monte‐Carlo simulation
Acta Ophthalmologica · 2024
DOI: 10.1111/aos.15726 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Ophthalmologica, 2024. Verfasst von Achim Langenbucher und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental Ophthalmology, Saarland University, Homburg, Germany. Hauptthemen laut MEDLINE: Lenses, Intraocular, Cataract, Phacoemulsification. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The purpose of this study was to investigate the uncertainty in the formula predicted refractive outcome REFU after cataract surgery resulting from measurement uncertainties in modern optical biometers using literature data for within‐subject standard deviation S w .
Methods
This Monte–Carlo simulation study used a large dataset containing 16 667 preoperative IOLMaster 700 biometric measurements. Based on literature S w values, REFU was derived for both the Haigis and Castrop formulae using error propagation strategies. Using the Hoya Vivinex lens (IOL) as an example, REFU was calculated both with (WLT) and without (WoLT) consideration of IOL power labelling tolerances.
Results
WoLT the median REFU was 0.10/0.12 dpt for the Haigis/Castrop formula, and WLT it was 0.13/0.15 dpt. WoLT REFU increased systematically for short eyes (or high power IOLs), and WLT this effect was even more pronounced because of increased labelling tolerances. WoLT the uncertainty in the measurement of the corneal front surface radius showed the largest contribution to REFU, especially in long eyes (and low power IOLs). WLT the IOL power uncertainty dominated in short eyes (or high power IOLs) and the uncertainty of the corneal front surface in long eyes (or low power IOLs).
Conclusions
Compared with published data on the formula prediction error of refractive outcome after cataract surgery, the uncertainty of biometric measures seems to contribute with ⅓ to ½ to the entire standard deviation. REFU systematically increases with IOL power and decreases with axial length.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Experimental Ophthalmology, Saarland University, Homburg, Germany.
- Augen- und Laserklinik Castrop-Rauxel, Castrop-Rauxel, Germany.
- School of Physical Sciences, The Open University, Milton Keynes, UK.
- Department of Ophthalmology, Johannes Kepler University Linz, Austria.
- Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, Homburg, Germany.
- Department of Ophthalmology, Semmelweis-University, Budapest, Hungary.
ORCID-Profile: Achim Langenbucher, Matthias Bolz, Jascha Wendelstein, Nóra Szentmáry
Zitieren
APA
Langenbucher, A., Hoffmann, P., Cayless, A., Bolz, M., Wendelstein, J., & Szentmáry, N. (2024). Impact of uncertainties in biometric parameters on intraocular lens power formula predicted refraction using a Monte‐Carlo simulation. Acta Ophthalmologica. https://doi.org/10.1111/aos.15726
Vancouver
Langenbucher A, Hoffmann P, Cayless A, Bolz M, Wendelstein J, Szentmáry N. Impact of uncertainties in biometric parameters on intraocular lens power formula predicted refraction using a Monte‐Carlo simulation. Acta Ophthalmologica. 2024. doi:10.1111/aos.15726
BibTeX
@article{Langenbucher2024,
author = {Langenbucher, Achim and Hoffmann, Peter and Cayless, Alan and Bolz, Matthias and Wendelstein, Jascha and Szentmáry, Nóra},
title = {Impact of uncertainties in biometric parameters on intraocular lens power formula predicted refraction using a Monte‐Carlo simulation},
journal = {Acta Ophthalmologica},
year = {2024},
doi = {10.1111/aos.15726}
}
EUVIMED