Restoring Arterial Pulsatility via Speed Modulation in Ventricular Assist Devices: A Structured Narrative Review and Mechanistic Windkessel‐Based Analysis
Artificial Organs · 13.11.2026
DOI: 10.1111/aor.70286 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Artificial Organs, online erschienen am 13.11.2026. Verfasst von Peng Fang und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot, China. Die Arbeit nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Inner Mongolia Autonomous Region, Basic Research Funds for Universities Directly Administered by the Inner Mongolia Autonomous Region.
Abstract (Originalsprache)
Background
Continuous‐flow ventricular assist devices (CF‐VADs) attenuate arterial pulsatility, potentially predisposing patients to complications such as endothelial dysfunction and gastrointestinal bleeding. Speed modulation has been proposed to reconstruct arterial pulsatility, but its effectiveness and underlying mechanisms remain incompletely understood.
Methods
A structured narrative review was conducted using studies identified from PubMed, Scopus, and Web of Science through June 2026. Evidence from animal experiments, mock circulatory loop studies, lumped‐parameter models, and clinical investigations was synthesized. A Windkessel‐based framework was used to interpret the effects of modulation parameters on arterial pulsatility.
Results
Animal and computational studies generally demonstrate that speed modulation can enhance arterial pulsatility, with the enhancement depending on factors such as modulation amplitude, waveform, frequency (i.e., the duration of high‐ and low‐speed phases) and phase relationship. Windkessel‐based analysis further indicates that pulsatility enhancement is governed by differences in flow‐time integrals between modulation phases, providing a mechanistic explanation for the observed effects of modulation parameters. However, clinically implemented speed modulation algorithms have not consistently produced significant improvements in arterial pulsatility or vascular function.
Conclusions
Speed modulation can enhance arterial pulsatility under animal and computational conditions, but its clinical effectiveness remains limited. This discrepancy may reflect constraints on modulation amplitude and duration imposed by hemocompatibility, ventricular safety, and device reliability. Future research should integrate multiscale hemodynamic and hemocompatibility assessments, long‐term animal and clinical validation, and advanced device designs and control strategies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot, China.
ORCID-Profile: Peng Fang
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Inner Mongolia Autonomous Region
- Basic Research Funds for Universities Directly Administered by the Inner Mongolia Autonomous Region
- Research Start-up Fund of Inner Mongolia University of Technology
- Inner Mongolia Autonomous Region Program for Innovation and Entrepreneurship Support for Returned Overseas Scholars
Zitieren
APA
Fang, P., An, Z., Feng, H., Wang, R., Zhang, Y., & Wang, J. (2026). Restoring Arterial Pulsatility via Speed Modulation in Ventricular Assist Devices: A Structured Narrative Review and Mechanistic Windkessel‐Based Analysis. Artificial Organs. https://doi.org/10.1111/aor.70286
Vancouver
Fang P, An Z, Feng H, Wang R, Zhang Y, Wang J. Restoring Arterial Pulsatility via Speed Modulation in Ventricular Assist Devices: A Structured Narrative Review and Mechanistic Windkessel‐Based Analysis. Artificial Organs. 2026. doi:10.1111/aor.70286
BibTeX
@article{Fang2026,
author = {Fang, Peng and An, Zhongqi and Feng, Haiquan and Wang, Rundong and Zhang, Yating and Wang, Jinbo},
title = {Restoring Arterial Pulsatility via Speed Modulation in Ventricular Assist Devices: A Structured Narrative Review and Mechanistic Windkessel‐Based Analysis},
journal = {Artificial Organs},
year = {2026},
doi = {10.1111/aor.70286}
}
EUVIMED