Magnetic Resonance Imaging Evaluation of Functional Differences Between In Vivo Human Kidneys and Discarded Human Kidneys During Ex Vivo Normothermic Machine Perfusion
Artificial Organs · 2026-07 · 50 (7) · 1037-1051
DOI: 10.1111/aor.70142 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Artificial Organs, online erschienen am 27.04.2026. Verfasst von Tim L Hamelink und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands. Hauptthemen laut MEDLINE: Kidney, Perfusion, Magnetic Resonance Imaging, Kidney Transplantation. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NCATS NIH HHS, Indiana Clinical and Translational Sciences Institute.
Abstract (Originalsprache)
Background
With increasing interest in renal normothermic machine perfusion (NMP), a deeper understanding of ex vivo renal physiology is essential to establish NMP as a robust pre‐transplant assessment platform. This study utilized magnetic resonance imaging (MRI) to compare in vivo renal physiology in healthy volunteers with ex vivo renal function of human donor kidneys during NMP.
Methods
Multiparametric MRI maps assessing water diffusion, oxygenation, tissue characteristics, and perfusion were obtained from 11 healthy volunteers to define an in vivo renal reference frame. For ex vivo evaluation, 25 discarded human donor kidneys underwent 4 h of oxygenated hypothermic machine perfusion, followed by 6 h of NMP in an MRI‐compatible setup. The kidneys were assessed hourly using comparable MRI modalities as in vivo.
Results
Ex vivo renal physiology was substantially different from in vivo physiology in terms of MRI‐based diffusion patterns, oxygenation, tissue characteristics, and tissue perfusion. Most MRI measurements did not correlate well with conventional parameters such as flow, renal function, and injury markers during NMP.
Conclusions
Our findings highlight distinct differences between in vivo and ex vivo MRI‐based renal characteristics in a human cohort, suggesting that parameters beyond conventional in vivo functional markers may warrant consideration when evaluating organ viability during NMP.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
- 34 Lives, Public Benefit Corporation, West-Lafayette, Indiana, USA.
- Department of Radiology, University Medical Center Groningen, Groningen, the Netherlands.
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
- School of Health Sciences, Purdue University, West-Lafayette, Indiana, USA.
- Department of Urology, Aarhus University Hospital, Aarhus, Denmark.
ORCID-Profile: Tim L Hamelink, Chris L Jaynes, L Annick van Furth, Johannes Castelein, Nathan Ooms, Veerle A Lantinga, Baran Ogurlu, Xiaopeng Zhou, Ulrike Dydak, Henri G D Leuvenink, Anna Krarup Keller, Ronald J H Borra, Cyril Moers
Förderung
- NIH HHS
- NCATS NIH HHS
- Indiana Clinical and Translational Sciences Institute
- European Research Council
Zitieren
APA
Hamelink, T. L., Jaynes, C. L., van Furth, L. A., Castelein, J., Ooms, N., Lantinga, V. A., Ogurlu, B., Zhou, X., Dydak, U., Leuvenink, H. G. D., Keller, A. K., Borra, R. J. H., & Moers, C. (2026). Magnetic Resonance Imaging Evaluation of Functional Differences Between In Vivo Human Kidneys and Discarded Human Kidneys During Ex Vivo Normothermic Machine Perfusion. Artificial Organs, 50(7), 1037-1051. https://doi.org/10.1111/aor.70142
Vancouver
Hamelink TL, Jaynes CL, van Furth LA, Castelein J, Ooms N, Lantinga VA, et al. Magnetic Resonance Imaging Evaluation of Functional Differences Between In Vivo Human Kidneys and Discarded Human Kidneys During Ex Vivo Normothermic Machine Perfusion. Artificial Organs. 2026;50(7):1037-1051. doi:10.1111/aor.70142
BibTeX
@article{Hamelink2026,
author = {Hamelink, Tim L and Jaynes, Chris L and van Furth, L Annick and Castelein, Johannes and Ooms, Nathan and Lantinga, Veerle A and Ogurlu, Baran and Zhou, Xiaopeng and Dydak, Ulrike and Leuvenink, Henri G D and Keller, Anna Krarup and Borra, Ronald J H and Moers, Cyril},
title = {Magnetic Resonance Imaging Evaluation of Functional Differences Between In Vivo Human Kidneys and Discarded Human Kidneys During Ex Vivo Normothermic Machine Perfusion},
journal = {Artificial Organs},
year = {2026},
volume = {50},
number = {7},
pages = {1037--1051},
doi = {10.1111/aor.70142}
}
EUVIMED