EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Vasoreactivity as a Measure of Kidney Viability During Ex Vivo Normothermic Machine Perfusion

Isa M van Tricht iD, Baran Ogurlu iD, Silke S M Wolfswinkel, Henri G D Leuvenink, Cyril Moers

Artificial Organs · 2026

DOI: 10.1111/aor.70033 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2026. Verfasst von Isa M van Tricht und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery-Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands. Hauptthemen laut MEDLINE: Kidney, Perfusion, Organ Preservation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nierstichting.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Normothermic machine perfusion (NMP) could serve as a platform to assess deceased‐donor kidney viability before transplantation, yet it remains unclear which parameters indicate renal viability. As vascular integrity is important for adequate renal function after transplantation, this study aimed to investigate the influence of warm ischemic injury on vascular smooth muscle cell (VSMC) responsiveness to vasoactive drugs during NMP.

Methods

Fourteen porcine kidneys ( n = 7 per group) were exposed to either 30 or 60 min of warm ischemia (WI), followed by 3.5 h of cold machine perfusion. After cold perfusion, kidneys underwent 4 h of NMP (37°C). During NMP, vasoactive drugs were sequentially infused into the renal artery at 30‐min intervals, starting with epoprostenol (10 μg), followed by dopamine (1 mg), sodium nitroprusside (2 mg), acetylcholine (1 mg), norepinephrine (10 μg), and finally verapamil (2.5 mg).

Results

Renal blood flow during NMP changed significantly in both groups after administration of dopamine, acetylcholine, norepinephrine, and verapamil, but not following epoprostenol and sodium nitroprusside infusion. In kidneys subjected to 30 min of WI, the response to dopamine and norepinephrine was more pronounced, and oxygen consumption and blood pH were higher compared to kidneys that sustained 60 min of WI.

Conclusion

This study indicates that prolonged WI damage diminishes the contractility of VSMCs through the α‐adrenergic receptors. Our findings suggest that the renal vascular responses to dopamine and norepinephrine, as well as decreased oxygen consumption and blood pH, could serve as objective indicators to quantify warm ischemic injury during renal NMP.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KidneyPerfusionOrgan PreservationAnimalsSwineWarm IschemiaVasodilator AgentsMuscle, Smooth, VascularRenal CirculationVasoconstrictor AgentsKidney Transplantation

Stichwörter der Autor:innen

drugskidneynormothermic machine perfusionpharmacologyporcinetransplantationvasoreactivitywarm ischemia

Substanzen

Vasodilator AgentsVasoconstrictor Agents

Autor:innen und Institutionen

  • Department of Surgery-Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.

ORCID-Profile: Isa M van Tricht, Baran Ogurlu

Förderung

  • Nierstichting

Zitieren

APA

van Tricht, I. M., Ogurlu, B., Wolfswinkel, S. S. M., Leuvenink, H. G. D., & Moers, C. (2026). Vasoreactivity as a Measure of Kidney Viability During Ex Vivo Normothermic Machine Perfusion. Artificial Organs. https://doi.org/10.1111/aor.70033

Vancouver

van Tricht IM, Ogurlu B, Wolfswinkel SSM, Leuvenink HGD, Moers C. Vasoreactivity as a Measure of Kidney Viability During Ex Vivo Normothermic Machine Perfusion. Artificial Organs. 2026. doi:10.1111/aor.70033

BibTeX
@article{vanTricht2026,
  author = {van Tricht, Isa M and Ogurlu, Baran and Wolfswinkel, Silke S M and Leuvenink, Henri G D and Moers, Cyril},
  title = {Vasoreactivity as a Measure of Kidney Viability During Ex Vivo Normothermic Machine Perfusion},
  journal = {Artificial Organs},
  year = {2026},
  doi = {10.1111/aor.70033}
}
Kostenlos starten →