The Neurophysiological Effects of Cervical Transcutaneous Spinal Cord Stimulation With and Without a High Frequency Carrier in Able‐Bodied Adults
Artificial Organs · 2025-12 · 49 (12) · 1799-1808
DOI: 10.1111/aor.15031 ↗Kurz gefasst
Fachartikel in der Zeitschrift Artificial Organs, online erschienen am 03.06.2025. Verfasst von Frances Gawne und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics and Biomedical Engineering, University College London, London, UK. Hauptthemen laut MEDLINE: Spinal Cord Stimulation, Spinal Cord Injuries, Transcutaneous Electric Nerve Stimulation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Transcutaneous spinal cord stimulation (tSCS) is a promising avenue in spinal cord injury (SCI) rehabilitation; however, high currents are required to excite afferents in the spinal cord roots, which patients may not tolerate. Modulating tSCS pulses with a kHz carrier frequency (kHz‐tSCS) may be used to reduce discomfort; however, the way that kHz‐tSCS interacts with neural networks, compared to unmodulated pulses (conv‐tSCS), is largely unknown.
Method
Ten able‐bodied participants received conv‐tSCS, kHz‐tSCS, and sham interventions for 20 min over the C7/T1 vertebrae. Charge delivery of both waveforms was measured. Posterior root reflexes (PRRs) and motor‐evoked potentials (MEPs) were recorded from the Flexor Carpi Radialis (FCR), Extensor Carpi Radialis Longus (ECRL), Flexor Carpi Ulnaris (FCU), and Brachioradialis (BR). PRR and MEP peak‐peak amplitudes were measured at baseline, 0‐, 15‐, and 30‐min post‐intervention.
Results
The charge required to activate posterior roots with kHz‐tSCS was 3.8 times higher than with conv‐tSCS ( p < 0.001). Differences in PRR amplitude were found in the FCR between conv‐tSCS and kHz‐tSCS at 0‐ and 15‐min post‐intervention ( p < 0.028). PRR inhibition was found in the FCR between baseline and 30‐min post‐intervention with conv‐tSCS and the sham intervention ( p < 0.037). No change in PRR amplitudes was found for kHz‐tSCS. No other muscle showed any differences in PRR responses between intervention groups. Neither intervention caused any effect in MEP responses across time or between intervention groups. Conclusions kHz‐tSCS was a less efficient waveform for stimulation. Differences in effects on spinal excitability were found to be inconclusive, and conv‐tSCS and kHz‐tSCS had no effect on corticospinal excitability. Significant PRR inhibition in the FCR was found with this experimental setup even when no stimulation was applied, suggesting a natural reduction in spinal excitability caused by participants laying supine for an extended period. Future research should consider how participant positioning could affect neural excitability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK.
- Aspire Centre for Rehabilitation Engineering and Assistive Technology, UCL Institute of Orthopaedics and Musculoskeletal Sciences, Royal National Orthopaedics Hospital, London, UK.
ORCID-Profile: Frances Gawne, Lynsey Duffell
Zitieren
APA
Gawne, F., Massey, S., & Duffell, L. (2025). The Neurophysiological Effects of Cervical Transcutaneous Spinal Cord Stimulation With and Without a High Frequency Carrier in Able‐Bodied Adults. Artificial Organs, 49(12), 1799-1808. https://doi.org/10.1111/aor.15031
Vancouver
Gawne F, Massey S, Duffell L. The Neurophysiological Effects of Cervical Transcutaneous Spinal Cord Stimulation With and Without a High Frequency Carrier in Able‐Bodied Adults. Artificial Organs. 2025;49(12):1799-1808. doi:10.1111/aor.15031
BibTeX
@article{Gawne2025,
author = {Gawne, Frances and Massey, Sarah and Duffell, Lynsey},
title = {The Neurophysiological Effects of Cervical Transcutaneous Spinal Cord Stimulation With and Without a High Frequency Carrier in Able‐Bodied Adults},
journal = {Artificial Organs},
year = {2025},
volume = {49},
number = {12},
pages = {1799--1808},
doi = {10.1111/aor.15031}
}