Fachartikel in der Zeitschrift Artificial Organs, 2025. Verfasst von Roohi Chhabra und 1 weiteren Autor:innen. Beteiligte Einrichtung: UCL Centre for Kidney & Bladder Health, Royal Free Hospital, University College London, London, UK. Hauptthemen laut MEDLINE: Renal Dialysis, Pulse Wave Analysis, Vascular Stiffness, Aorta. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pulse wave velocity (PWV), a measurement of arterial stiffness, is a risk factor for cardiovascular mortality in hemodialysis patients. Debate continues as to whether PWV is increased by volume overload. As such, we reviewed the association between volume overload and PWV.

Methods

We measured aortic PWV (aPWV) in hemodialysis patients attending routine dialysis sessions with contemporaneous measurements of extracellular water/total body water (ECW/TBW) ratios using multifrequency bioimpedance.

Results

A total of 102 patients, 63.7% male, mean age 63.5 ± 15.9 years, 44.1% diabetic, median dialysis duration 22.2 (4.9–52.8) months, weight 73.7 ± 15.8 kg, and central systolic blood pressure 157 ± 35 mmHg had a mean aPWV of 10.1 ± 2.5 m/s. Patients dialyzed with a low dialysate calcium (median 1.0 [1.0–1.25] mmol/L). Patients with aPWV of ≥ 10 m/s were older (72.9 ± 10.3 vs. 52.6 ± 14.4 years, p < 0.01) with a higher ECW/TBW ratio (40.6 ± 1.3 vs. 39.6 ± 1.7, p < 0.001), with no differences in active vitamin D 3 or calcium‐containing medications. Aortic PWV was associated with age ( r = 0.9, p < 0.001) and ECW/TBW ( r = 0.33, p = < 0.001), and after adjusting aPWV for age, ECW/TBW remained higher (40.5 ± 1.5 vs. 39.5 ± 1.5, p < 0.001). On multivariable testing, ECW/TBW remained independently associated with a raised aPWV (odds ratio [OR] 1.59 (95% confidence intervals [CI] 1.06–2.41), p = 0.026), and after age adjustment (OR 1.74 (95% CI 1.19–2.53, p = 0.004)).

Conclusions

This study highlights the association between volume overload, as determined by bioimpedance in hemodialysis patients, and arterial stiffness measured by aPWV. These results would reinforce the importance of improving volume control in hemodialysis patients to reduce cardiovascular risk.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal DialysisPulse Wave AnalysisVascular StiffnessAortaBody WaterKidney Failure, ChronicHumansMaleMiddle AgedFemaleAgedRisk Factors

Stichwörter der Autor:innen

bioimpedancehemodialysishypertensionmortalitypulse wave velocity

Autor:innen und Institutionen

  • UCL Centre for Kidney & Bladder Health, Royal Free Hospital, University College London, London, UK.

Zitieren

APA

Chhabra, R., & Davenport, A. (2025). Aortic Pulse Wave Velocity and Extracellular Water Expansion in Hemodialysis Patients. Artificial Organs. https://doi.org/10.1111/aor.15015

Vancouver

Chhabra R, Davenport A. Aortic Pulse Wave Velocity and Extracellular Water Expansion in Hemodialysis Patients. Artificial Organs. 2025. doi:10.1111/aor.15015

BibTeX
@article{Chhabra2025,
  author = {Chhabra, Roohi and Davenport, Andrew},
  title = {Aortic Pulse Wave Velocity and Extracellular Water Expansion in Hemodialysis Patients},
  journal = {Artificial Organs},
  year = {2025},
  doi = {10.1111/aor.15015}
}
Kostenlos starten →