EUVIMEDEUVIMED entdecken
Crossref

Sequential Hypothermic and Normothermic Machine Perfusion of Extended Criteria Donors in Liver Transplantation: A Single‐Center Preliminary Experience

Paolo Magistri iD, Silvia Zamboni, Barbara Catellani, Cristiano Guidetti, Giuseppe Esposito iD, Daniela Caracciolo, Roberta Odorizzi, Giacomo Assirati, Tiziana Olivieri, Samuele Frassoni, Vincenzo Bagnardi, Gian Piero Guerrini und 2 weitere

Artificial Organs · 2025-04 · 49 (4) · 705-715

DOI: 10.1111/aor.14936 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, online erschienen am 19.02.2025. Verfasst von Paolo Magistri und 13 weiteren Autor:innen. Beteiligte Einrichtung: Hepato-Pancreato-Biliary Surgery and Liver Transplantation Unit, University Hospital of Modena "Policlinico", University of Modena and Reggio Emilia,…. Hauptthemen laut MEDLINE: Liver Transplantation, Organ Preservation, Perfusion. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Liver transplantation (LT) is the sole curative option for liver failure and other primary liver conditions. However, the limited number of suitable donors compared with the growing number of patients requiring LT remains a leading cause of mortality among those on the waiting list. This has resulted in the expansion of criteria for donor eligibility. The sequential combination of ex situ reperfusion, dHOPE, and NMP helps reduce the occurrence of ischemia–reperfusion injury and assess organ viability prior to transplantation.

Methods

This is a retrospective, single‐arm, single‐center study including all cases of liver grafts that underwent sequential perfusion between October 2021 and July 2024. Eligibility criteria for sequential perfusion were extended criteria DBD with macrosteatosis > 35%, use of high‐dose vasopressors during donor ICU stay or episodes of cardiac arrest, hemodynamic instability during procurement, prolonged ischemia time for logistic reasons, as well as DCD showing prolonged fWIT, flow alteration during normothermic regional perfusion (NRP), and DCDs in Maastricht 2 class. Viability was assessed following the Groeningen group criteria.

Results

Thirty‐three cases were included and 16 met the viability criteria at the end of the sequential perfusion and were transplanted. One patient developed an early allograft failure (EAF) and another a primary nonfunction (PNF). All the other patients had a regular postoperative course, with no retransplantation, 56% of the cohort showing no postoperative complication and all currently in good standing, median follow‐up 19 months (range 4–39).

Conclusions

Sequential dHOPE and NMP is a strategy that can help assessing both viability and functionality of liver grafts from high‐risk donors, expanding the donor pool and increasing the opportunities for patients on the waiting list to get a transplant.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liver TransplantationOrgan PreservationPerfusionAdultAgedFemaleHumansMaleMiddle AgedGraft SurvivalRetrospective StudiesTissue DonorsAdolescentYoung AdultAged, 80 and over

Autor:innen und Institutionen

  • Hepato-Pancreato-Biliary Surgery and Liver Transplantation Unit, University Hospital of Modena "Policlinico", University of Modena and Reggio Emilia, Modena, Italy.
  • Department of Statistics and Quantitative Methods, University of Milano-Bicocca, Milan, Italy.
  • Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy.

ORCID-Profile: Paolo Magistri, Giuseppe Esposito

Zitieren

APA

Magistri, P., Zamboni, S., Catellani, B., Guidetti, C., Esposito, G., Caracciolo, D., Odorizzi, R., Assirati, G., Olivieri, T., Frassoni, S., Bagnardi, V., Guerrini, G. P., Di Sandro, S., & Di Benedetto, F. (2025). Sequential Hypothermic and Normothermic Machine Perfusion of Extended Criteria Donors in Liver Transplantation: A Single‐Center Preliminary Experience. Artificial Organs, 49(4), 705-715. https://doi.org/10.1111/aor.14936

Vancouver

Magistri P, Zamboni S, Catellani B, Guidetti C, Esposito G, Caracciolo D, et al. Sequential Hypothermic and Normothermic Machine Perfusion of Extended Criteria Donors in Liver Transplantation: A Single‐Center Preliminary Experience. Artificial Organs. 2025;49(4):705-715. doi:10.1111/aor.14936

BibTeX
@article{Magistri2025,
  author = {Magistri, Paolo and Zamboni, Silvia and Catellani, Barbara and Guidetti, Cristiano and Esposito, Giuseppe and Caracciolo, Daniela and Odorizzi, Roberta and Assirati, Giacomo and Olivieri, Tiziana and Frassoni, Samuele and Bagnardi, Vincenzo and Guerrini, Gian Piero and Di Sandro, Stefano and Di Benedetto, Fabrizio},
  title = {Sequential Hypothermic and Normothermic Machine Perfusion of Extended Criteria Donors in Liver Transplantation: A Single‐Center Preliminary Experience},
  journal = {Artificial Organs},
  year = {2025},
  volume = {49},
  number = {4},
  pages = {705--715},
  doi = {10.1111/aor.14936}
}
Kostenlos starten →