Aortic regurgitation in left ventricular assist device patients: Does aortic root dilatation contribute to valve incompetence?
Artificial Organs · 2025
DOI: 10.1111/aor.14873 ↗Kurz gefasst
Fachartikel in der Zeitschrift Artificial Organs, 2025. Verfasst von Gloria Färber und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Saarland University Medical Center, Homburg/Saar, Germany. Hauptthemen laut MEDLINE: Heart-Assist Devices, Aortic Valve Insufficiency, Heart Failure, Aortic Valve. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Background
Aortic regurgitation (AR) is a known complication after left ventricular assist device (LVAD) implantation potentially leading to recurrent heart failure. Possible pathomechanisms include valvular pathologies and aortic root dilatation. We assessed aortic root dimensions in a group of consecutive LVAD patients who received HeartMate 3.
Methods
Since 11/2015, we identified 68 patients with no or mild AR at the time of HeartMate 3 implantation who underwent serial echocardiography to assess AR and aortic root dimensions (annulus, sinus, and sinotubular junction). Median follow‐up was 40 months (2–94 months). Results were correlated with clinical outcomes.
Results
Patients were 60 ± 10 years old, predominantly male (88%) and 35% presented in preoperative critical condition as defined by INTERMACS levels 1 and 2. During follow‐up, 23 patients developed AR ≥ II (34%). Actuarial incidence was 8% at 1 year, 29% at 3 years and 41% at 5 years. Echocardiography revealed practically stable root dimensions at the latest follow‐up compared to the preoperative state (annulus: 23 ± 3 mm vs. 23 ± 2 mm, sinus: 32 ± 4 mm vs. 33 ± 3 mm, sinotubular junction: 27 ± 3 mm vs. 28 ± 3 mm), irrespective of the development of AR. Serial CT angiograms were performed in 13 patients to confirm echocardiographic findings. Twenty‐one patients died during LVAD support leading to a 5‐year survival of 71%, showing no difference between patients with and without AR ≥ II ( p = 0.573).
Conclusions
At least moderate AR develops over time in a substantial fraction of patients (one‐third over 3 years). The mechanism does not seem to be related to dilatation of the aortic annulus or root.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery, Saarland University Medical Center, Homburg/Saar, Germany.
- Department of Radiology, University Hospital Jena, Friedrich Schiller University, Jena, Germany.
- Department of Cardiothoracic Surgery, University Hospital Jena, Friedrich Schiller University, Jena, Germany.
- Department of Cardiac Surgery, Herz- und Kreislaufzentrum, Rotenburg an der Fulda, Germany.
ORCID-Profile: Gloria Färber, Ulrich Schneider, Stephanie Gräger
Zitieren
APA
Färber, G., Schneider, U., Gräger, S., Elayan, Y., Schwan, I., Tkebuchava, S., Kirov, H., Caldonazo, T., Diab, M., & Doenst, T. (2025). Aortic regurgitation in left ventricular assist device patients: Does aortic root dilatation contribute to valve incompetence?. Artificial Organs. https://doi.org/10.1111/aor.14873
Vancouver
Färber G, Schneider U, Gräger S, Elayan Y, Schwan I, Tkebuchava S, et al. Aortic regurgitation in left ventricular assist device patients: Does aortic root dilatation contribute to valve incompetence?. Artificial Organs. 2025. doi:10.1111/aor.14873
BibTeX
@article{Frber2025,
author = {Färber, Gloria and Schneider, Ulrich and Gräger, Stephanie and Elayan, Yousef and Schwan, Imke and Tkebuchava, Sophie and Kirov, Hristo and Caldonazo, Tulio and Diab, Mahmoud and Doenst, Torsten},
title = {Aortic regurgitation in left ventricular assist device patients: Does aortic root dilatation contribute to valve incompetence?},
journal = {Artificial Organs},
year = {2025},
doi = {10.1111/aor.14873}
}
EUVIMED