Renal resistive index in patients supported with a durable continuous flow left ventricular assist device

S Barua iD, D Robson iD, H Eckford, P Macdonald iD, K Muthiah iD, C S Hayward iD

Artificial Organs · 2024

DOI: 10.1111/aor.14854 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2024. Verfasst von S Barua und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, St Vincent's Hospital Sydney, Darlinghurst, New South Wales, Australia. Hauptthemen laut MEDLINE: Heart-Assist Devices, Vascular Resistance, Heart Failure, Kidney. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The impact of continuous flow resulting from contemporary left ventricular assist devices (LVAD) on renal vascular physiology is unknown. Renal resistive index (RRI) reflects arterial compliance, as well as renal vascular resistance, contributed by afferent and efferent arteriolar tone, the renal interstitium as well as renal venous pressures.

Methods

Prospective, single center study with renal Doppler evaluation at baseline (pre‐implant) and at 3‐months support. Outcomes assessed include need for post‐operative renal replacement therapy (RRT), worsening renal function (WRF) defined as persistent increase from pre‐implant KDIGO chronic kidney disease stage, right ventricular (RV) failure, and survival to transplantation.

Results

Pre‐implant RRI did not predict cardiorenal outcomes including right heart failure, need for renal replacement therapy or worsening renal function. Post‐implant RRI was significantly lower than pre‐implant RRI, with a distinct Doppler waveform characteristic of continuous flow. Post‐implant renal end‐diastolic velocity, but not RRI, correlated strongly with LVAD flow (Spearman rho −0.99, p < 0.001), with trend toward correlation with mean arterial pressure (Spearman's rho 0.63, p = 0.129). There was a negative correlation between post‐implant RRI and mean pulmonary artery pressure (Spearman's rho −0.81, p = 0.049), likely driven by elevated pulmonary capillary wedge pressure (Spearman's rho −0.83, p = 0.058).

Conclusion

The hemodynamic contributors to RRI in LVAD supported patients are complex. Higher mean pulmonary artery and pulmonary capillary wedge pressures seen in lower RRI may reflect a smaller difference in systolic and diastolic flow. Future simultaneous Doppler assessment of the LVAD outflow graft and RRI may help understand the hemodynamic interactions contributing to this index.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesVascular ResistanceHeart FailureKidneyHumansMaleMiddle AgedProspective StudiesFemaleAgedAdultUltrasonography, Doppler

Stichwörter der Autor:innen

left ventricular assist devicerenal resistive indexworsening renal function

Autor:innen und Institutionen

  • Department of Cardiology, St Vincent's Hospital Sydney, Darlinghurst, New South Wales, Australia.
  • University of New South Wales School of Medicine, Kensington, New South Wales, Australia.
  • Victor Chang Cardiac Research Institute, Darlinghurst, New South Wales, Australia.
  • Faculty of Health, University of Technology Sydney, Ultimo, New South Wales, Australia.

ORCID-Profile: S Barua, D Robson, P Macdonald, K Muthiah, C S Hayward

Zitieren

APA

Barua, S., Robson, D., Eckford, H., Macdonald, P., Muthiah, K., & Hayward, C. S. (2024). Renal resistive index in patients supported with a durable continuous flow left ventricular assist device. Artificial Organs. https://doi.org/10.1111/aor.14854

Vancouver

Barua S, Robson D, Eckford H, Macdonald P, Muthiah K, Hayward CS. Renal resistive index in patients supported with a durable continuous flow left ventricular assist device. Artificial Organs. 2024. doi:10.1111/aor.14854

BibTeX
@article{Barua2024,
  author = {Barua, S and Robson, D and Eckford, H and Macdonald, P and Muthiah, K and Hayward, C S},
  title = {Renal resistive index in patients supported with a durable continuous flow left ventricular assist device},
  journal = {Artificial Organs},
  year = {2024},
  doi = {10.1111/aor.14854}
}