EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Computational fluid dynamics‐based design and in vitro characterization of a novel pediatric pump‐lung

Dong Han, Jiafeng Zhang, Ge He, Bartley P Griffith, Zhongjun J Wu iD

Artificial Organs · 2024

DOI: 10.1111/aor.14665 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2024. Verfasst von Dong Han und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Hemolysis, Extracorporeal Membrane Oxygenation. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Although extracorporeal membrane oxygenation (ECMO) has been used to provide temporary support for pediatric patients suffering severe respiratory or cardiac failure since 1970, ECMO systems specifically designed for pediatric patients, particularly for long‐term use, remain an unmet clinical need. We sought to develop a new pediatric ECMO system, that is, pediatric pump‐lung (PPL), consisting of a unique cylinder oxygenator with an outside‐in radial flow path and a centrifugal pump.

Methods

Computational fluid dynamics was used to analyze the blood fluid field for optimized biocompatible and gas exchange performances in terms of flow characteristics, hemolysis, and gas transfer efficiency. Ovine blood was used for in vitro hemolysis and gas transfer testing.

Results

Both the computational and experimental data showed that the pressure drop through the PPL's oxygenator is significantly low, even at a flow rate of more than 3.5 L/min. The PPL showed better hemolysis performance than a commercial ECMO circuit consisting of the Quadrox‐iD pediatric oxygenator and the Rotaflow pump at a 3.5 L/min flow rate and 250 mm Hg afterload pressure. The oxygen transfer rate of the PPL can reach over 200 mL/min at a flow rate of 3.5 L/min.

Conclusions

The PPL has the potential to provide adequate blood pumping and excellent respiratory support with minimal risk of hemolysis for a wide range of pediatric patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemolysisExtracorporeal Membrane OxygenationHumansChildAnimalsSheepHydrodynamicsLungOxygenatorsEquipment Design

Stichwörter der Autor:innen

CFDECMOgas transferhemolysisin vitropediatric pump-lung

Autor:innen und Institutionen

  • Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA.
  • Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, Maryland, USA.

ORCID-Profile: Zhongjun J Wu

Förderung

  • NHLBI NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Han, D., Zhang, J., He, G., Griffith, B. P., & Wu, Z. J. (2024). Computational fluid dynamics‐based design and in vitro characterization of a novel pediatric pump‐lung. Artificial Organs. https://doi.org/10.1111/aor.14665

Vancouver

Han D, Zhang J, He G, Griffith BP, Wu ZJ. Computational fluid dynamics‐based design and in vitro characterization of a novel pediatric pump‐lung. Artificial Organs. 2024. doi:10.1111/aor.14665

BibTeX
@article{Han2024,
  author = {Han, Dong and Zhang, Jiafeng and He, Ge and Griffith, Bartley P and Wu, Zhongjun J},
  title = {Computational fluid dynamics‐based design and in vitro characterization of a novel pediatric pump‐lung},
  journal = {Artificial Organs},
  year = {2024},
  doi = {10.1111/aor.14665}
}
Kostenlos starten →