XPS™ Jensen lung as a low‐cost, high‐fidelity training adjunct to ex‐vivo lung perfusion

Doug A Gouchoe iD, Basam Shukrallah, Chad Eggeman, David Igoe, James Ralston, David Mast, Asvin M Ganapathi iD, Bryan A Whitson

Artificial Organs · 2023

DOI: 10.1111/aor.14623 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2023. Verfasst von Doug A Gouchoe und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA. Hauptthemen laut MEDLINE: Lung Transplantation. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ex vivo lung perfusion (EVLP) enables lung resuscitation before transplantation, and training is key, particularly in low‐volume settings. To enable technique refinement and continuing education, we sought to demonstrate the value of a low‐cost, high‐fidelity EVLP simulator that would allow reproducible clinical scenarios.

Methods

In partnership with our EVLP manufacturer, we utilized the XPS™ Jensen Lung with our clinical system. The Jensen Lung has two simulated lung bladders and an in‐line polymethylpentene fiber oxygenator. It allows titration of ventilator support which aids in accurate clinical simulation. For simulations, blood gases (BGs) were obtained and compared with integrated in‐line perfusate gas monitors (PGMs). PaO 2 , PCO 2 , and pH were measured and compared.

Results

The PGM and BG values were not significantly different throughout the range of FiO 2 and sweep gas flow rates evaluated. The “delta” PaO 2 was measured between LA and PA and did not show any change between approaches. The pH measurement between BG and PGM was not significantly different.

Conclusions

The XPS™ Jensen Lung simulator allows for a high‐fidelity simulator of clinical EVLP. The correlation of the PGM and the BG measurement of the PaO 2 and pH allow for a low‐cost simulation, as the PGMs are in line in the circuit, and enable real‐time tracking of perfusate gas parameters with the PGM. Implementation of a standardized clinical EVLP training program allows the maintenance of technique and enables clinical simulation training without the need for costly animal perfusions and the use of multiple BG measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung TransplantationAnimalsLungExtracorporeal CirculationPerfusionGases

Stichwörter der Autor:innen

XPS™ Jensen lungex-vivo lung perfusionsurgical simulation

Substanzen

Gases

Autor:innen und Institutionen

  • Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • 88th Surgical Operations Squadron, Wright-Patterson Medical Center, WPAFB, Dayton, Ohio, USA.
  • Department of Surgery, University of Alabama School of Medicine, Birmingham, Alabama, USA.
  • XVIVO Perfusion, Inc, Englewood, Colorado, USA.

ORCID-Profile: Doug A Gouchoe, Asvin M Ganapathi

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Gouchoe, D. A., Shukrallah, B., Eggeman, C., Igoe, D., Ralston, J., Mast, D., Ganapathi, A. M., & Whitson, B. A. (2023). XPS™ Jensen lung as a low‐cost, high‐fidelity training adjunct to ex‐vivo lung perfusion. Artificial Organs. https://doi.org/10.1111/aor.14623

Vancouver

Gouchoe DA, Shukrallah B, Eggeman C, Igoe D, Ralston J, Mast D, et al. XPS™ Jensen lung as a low‐cost, high‐fidelity training adjunct to ex‐vivo lung perfusion. Artificial Organs. 2023. doi:10.1111/aor.14623

BibTeX
@article{Gouchoe2023,
  author = {Gouchoe, Doug A and Shukrallah, Basam and Eggeman, Chad and Igoe, David and Ralston, James and Mast, David and Ganapathi, Asvin M and Whitson, Bryan A},
  title = {XPS™ Jensen lung as a low‐cost, high‐fidelity training adjunct to ex‐vivo lung perfusion},
  journal = {Artificial Organs},
  year = {2023},
  doi = {10.1111/aor.14623}
}
Kostenlos starten →