Frequency of fetal blood sampling, delivery mode and neonatal outcome after revised CTG ‐classification and updated lactate meter in Sweden: An observational study
Acta Obstetricia et Gynecologica Scandinavica · 2025
DOI: 10.1111/aogs.15063 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Acta Obstetricia et Gynecologica Scandinavica, 2025. Verfasst von Klara Gröndal und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden. Hauptthemen laut MEDLINE: Cardiotocography, Fetal Blood, Lactic Acid, Delivery, Obstetric. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Region Stockholm, clinical research appointment, Unit of Research, Education and Development, Region Jämtland, Härjedalen.
Abstract (Originalsprache)
Introduction
A revised cardiotocography (CTG) classification was implemented in Sweden in 2017. Simultaneously, an updated version of the lactate meter, Lactate Pro 2™, proved to measure 50% higher than the previous, necessitating new cutoffs for fetal blood sampling (FBS). We aimed to investigate frequencies of FBS, delivery modes, and neonatal outcomes. We hypothesized that with the revised CTG classification, which accepts more fetal heart rate patterns as normal than the previous, the frequency of FBS would be lower, the proportion of acidemia at FBS and adverse neonatal outcomes would be higher among sampled fetuses, but not among the entire laboring population, and the higher lactate readings might increase the proportion of cesarean delivery in general anesthesia and cesarean delivery above vacuum extraction. Material and Methods A population‐based cohort study of electronic medical records of labors in Stockholm‐Gotland during 2014–2015 and 2018–2019, including singleton pregnancies >34 weeks, cephalic presentation, with spontaneous or induced start of labor. Outcome measures were FBS frequency, proportion of fetal acidemia, delivery modes, and neonatal outcomes with comparison between the two periods among sampled and nonsampled fetuses.
Results
There were 28 841 and 30 192 births during the two periods. In the latter period, the FBS frequency was lower (8.2% vs. 11.9% [ p < 0.001]), and the proportion of acidemia at FBS was higher, both among sampled fetuses (12.5% vs. 7.1% [ p < 0.001]), and in the total population (1.0% vs. 0.8% [ p = 0.022]). Immediate cesareans in general anesthesia due to fetal distress were more frequent among sampled fetuses (3.1% vs. 2.0% [ p = 0.006]) but not among nonsampled fetuses (0.4 vs. 0.4%). Incidence of Apgar scores < 4 at 5 min was unchanged after FBS ( p = 0.66) but higher among nonsampled newborns (0.2 vs. 0.1 [ p = 0.033]). Apgar scores
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.
- Department of Obstetrics and Gynecology, Östersund Hospital, Östersund, Sweden.
- Medical Unit Pregnancy and Delivery Care, Karolinska University Hospital, Stockholm, Sweden.
- Department of Medicine Solna, Karolinska Institutet, Stockholm, Sweden.
ORCID-Profile: Erika Gyllencreutz, Malin Holzmann
Förderung
- Region Stockholm, clinical research appointment
- Unit of Research, Education and Development, Region Jämtland, Härjedalen
Zitieren
APA
Gröndal, K., Gyllencreutz, E., Wretler, S., Johansson, K., & Holzmann, M. (2025). Frequency of fetal blood sampling, delivery mode and neonatal outcome after revised CTG ‐classification and updated lactate meter in Sweden: An observational study. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/aogs.15063
Vancouver
Gröndal K, Gyllencreutz E, Wretler S, Johansson K, Holzmann M. Frequency of fetal blood sampling, delivery mode and neonatal outcome after revised CTG ‐classification and updated lactate meter in Sweden: An observational study. Acta Obstetricia et Gynecologica Scandinavica. 2025. doi:10.1111/aogs.15063
BibTeX
@article{Grndal2025,
author = {Gröndal, Klara and Gyllencreutz, Erika and Wretler, Stina and Johansson, Kari and Holzmann, Malin},
title = {Frequency of fetal blood sampling, delivery mode and neonatal outcome after revised CTG ‐classification and updated lactate meter in Sweden: An observational study},
journal = {Acta Obstetricia et Gynecologica Scandinavica},
year = {2025},
doi = {10.1111/aogs.15063}
}
EUVIMED