EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

What's in the Bin? A Waste Audit of an Australian Tertiary Ear, Nose and Throat Outpatient Clinic

Cassie Dow iD, Daron Cope iD, Robert Eisenberg iD

ANZ Journal of Surgery · 2026

DOI: 10.1111/ans.70526 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ANZ Journal of Surgery, 2026. Verfasst von Cassie Dow und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology, John Hunter Hospital, Newcastle, New South Wales, Australia. Hauptthemen laut MEDLINE: Ambulatory Care Facilities, Otolaryngology, Medical Waste, Disposable Equipment. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Healthcare contributes 4.4% of global emissions. Climate change contributes to vector‐borne diseases, food insecurity and morbidity and mortality associated with extreme weather. Ear, nose and throat (ENT) outpatient clinics are particularly resource intensive, yet their environmental impact has not been quantified. The aim of this study was to quantify waste generation in an ENT outpatient clinic and estimate associated carbon equivalent emissions produced.

Methods

Disposable waste from 20 consecutive ENT outpatient clinics at a tertiary Australian hospital was collected, counted and weighed in November 2024. Plastic packaging was also collected from 10 of these clinics and weighed. Published lifecycle assessments (LCA) were used to calculate global warming potential (GWP).

Results

Across 20 clinics, 292 patients were seen and 128 nasendoscopes used. Annually, 244.56 kg of clinical waste was estimated to be generated, associated with 10 606 pieces of plastic packaging (19.54 kg). The GWP associated with this was 996.154 kg of carbon dioxide equivalent emissions (kgCO 2 ‐e). In the clinic, re‐usable rhinolaryngoscopes generated 477.26 kgCO 2 ‐e annually. In total, the clinical waste, plastic packaging and use of re‐usable scopes equated to 1015.75 kgCO 2 ‐e annually, or 0.26 kgCO 2 ‐e per patient.

Conclusion

ENT outpatient clinics generate considerable waste and emissions from disposables and packaging. Sustainable practice requires collaboration between clinicians, manufacturers and infection control, with transparent LCA data and local assessments to inform procurement and align healthcare with sustainability goals. A potential saving equivalent of up to 1 t of carbon dioxide CO 2 ‐e was identified from a single tertiary ENT unit.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ambulatory Care FacilitiesOtolaryngologyMedical WasteDisposable EquipmentHumansAustraliaTertiary Care CentersMedical Waste Disposal

Stichwörter der Autor:innen

climate changedisposable equipmentenvironmentmedical wasteotolaryngology

Substanzen

Medical WasteMedical Waste Disposal

Autor:innen und Institutionen

  • Department of Otolaryngology, John Hunter Hospital, Newcastle, New South Wales, Australia.
  • School of Medicine and Public Health, University of Newcastle, Newcastle, New South Wales, Australia.

ORCID-Profile: Cassie Dow, Daron Cope, Robert Eisenberg

Zitieren

APA

Dow, C., Cope, D., & Eisenberg, R. (2026). What's in the Bin? A Waste Audit of an Australian Tertiary Ear, Nose and Throat Outpatient Clinic. ANZ Journal of Surgery. https://doi.org/10.1111/ans.70526

Vancouver

Dow C, Cope D, Eisenberg R. What's in the Bin? A Waste Audit of an Australian Tertiary Ear, Nose and Throat Outpatient Clinic. ANZ Journal of Surgery. 2026. doi:10.1111/ans.70526

BibTeX
@article{Dow2026,
  author = {Dow, Cassie and Cope, Daron and Eisenberg, Robert},
  title = {What's in the Bin? A Waste Audit of an Australian Tertiary Ear, Nose and Throat Outpatient Clinic},
  journal = {ANZ Journal of Surgery},
  year = {2026},
  doi = {10.1111/ans.70526}
}