EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Effect of Virtual Reality as Analgesia for Trans‐Rectal Ultrasound Prostate Biopsy on Pain Severity: A Prospectively Randomised Controlled Study

Christian Robinson iD, Amir D Zarrabi, Robin M Turner iD

ANZ Journal of Surgery · 2026

DOI: 10.1111/ans.70441 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift ANZ Journal of Surgery, 2026. Verfasst von Christian Robinson und 2 weiteren Autor:innen. Beteiligte Einrichtung: Southern District Health Board Department of Surgery, Dunedin Hospital, Dunedin, New Zealand. Hauptthemen laut MEDLINE: Virtual Reality, Analgesia, Pain Management, Prostate. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: USANZ Research Grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

TRUS Biopsy (TRUS Bx) can be poorly tolerated under local anaesthetic. Virtual Reality (VR) has been shown to reduce pain and anxiety levels as an adjunct to standard analgesia in a range of settings. This includes paediatric procedures, burn wound debridement and gynaecological procedures. However, its effect in TRUS Bx remains unclear. The aim of this study was to determine if intra‐procedure VR improved patient pain and satisfaction during TRUS Bx.

Method

A single‐centre, parallel‐group randomised controlled trial was conducted at Dunedin Hospital. Two hundred and fifty patients presenting for first TRUS Bx were randomised to either conventional TRUS or VR‐assisted TRUS over 36 months. The intervention group wore a VR headset with distraction video software, with the control group having standard care. The primary outcome measured patients' pain scores using a visual analogue scale.

Results

Patients reported similar pain when distracted with VR (mean difference [MD] –2.6, 95% CI –8.5 to 3.2). Similarly, there was no evidence of a difference in ‘time thinking about pain’ (MD 0.9, 95% CI –7.2 to 9.0) or ‘worst pain’ (pain intensity) (MD –2.4, 95% CI –8.6 to 3.8). Both groups were equally satisfied with the procedure and would happily accept having the procedure again if needed. VR was not associated with any side effects.

Conclusion

VR technology did not improve patients' pain and overall satisfaction with TRUS Bx. The inherent vulnerability and invasive nature of the procedure may impact the effectiveness of this distraction technique and prevent its analgesic effects proven in non‐urological studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Virtual RealityAnalgesiaPain ManagementProstateProcedural PainPainProstatic NeoplasmsImage-Guided BiopsyHumansMaleMiddle AgedProspective StudiesPain MeasurementAgedPatient SatisfactionAdult

Stichwörter der Autor:innen

analgesiaanxietybiopsypain measurementpatient satisfactionvirtual realityvisual analogue scale

Autor:innen und Institutionen

  • Southern District Health Board Department of Surgery, Dunedin Hospital, Dunedin, New Zealand.
  • Queenstown Urology, Dunedin, New Zealand.
  • Biostatistics Centre, Division of Health Sciences, University of Otago, Dunedin, New Zealand.

ORCID-Profile: Christian Robinson, Robin M Turner

Förderung

  • USANZ Research Grant

Zitieren

APA

Robinson, C., Zarrabi, A. D., & Turner, R. M. (2026). Effect of Virtual Reality as Analgesia for Trans‐Rectal Ultrasound Prostate Biopsy on Pain Severity: A Prospectively Randomised Controlled Study. ANZ Journal of Surgery. https://doi.org/10.1111/ans.70441

Vancouver

Robinson C, Zarrabi AD, Turner RM. Effect of Virtual Reality as Analgesia for Trans‐Rectal Ultrasound Prostate Biopsy on Pain Severity: A Prospectively Randomised Controlled Study. ANZ Journal of Surgery. 2026. doi:10.1111/ans.70441

BibTeX
@article{Robinson2026,
  author = {Robinson, Christian and Zarrabi, Amir D and Turner, Robin M},
  title = {Effect of Virtual Reality as Analgesia for Trans‐Rectal Ultrasound Prostate Biopsy on Pain Severity: A Prospectively Randomised Controlled Study},
  journal = {ANZ Journal of Surgery},
  year = {2026},
  doi = {10.1111/ans.70441}
}
Kostenlos starten →