Fachartikel in der Zeitschrift ANZ Journal of Surgery, 2025. Verfasst von Stanley Chen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Surgery, John Hunter Hospital, Newcastle, New South Wales, Australia. Hauptthemen laut MEDLINE: Equipment Reuse, Operating Rooms, Sterilization, Carbon Footprint. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Replacing single‐use operating theatre equipment with reusables might be one strategy for reducing the carbon footprint of operating theatres. However, in Australia, where the energy mix is predominantly fossil‐fuel‐based, the re‐sterilization of reusables may increase the carbon footprint. We analyzed the financial and environmental impacts of introducing reusable operating theatre light handles in two NSW hospitals.

Methods

The effects on cost, waste, and carbon footprint of replacing disposable light handle covers with reusable handles in each hospital were analyzed over 12 months using procurement, waste and sterilization data, and life cycle assessment.

Results

Energy requirement for sterilization of reusable handles, increasing alongside weight of the handle, resulted in higher carbon footprint than using disposable covers. At one hospital, using a heavy handle increased carbon emissions sixfold, while the cost of handle sterilization exceeded the cost of disposable covers, resulting in 11% higher cost per use. At the other hospital, using a lighter handle increased carbon emissions by 40% per use, while sterilization cost was less than the cost of disposable covers, resulting in 14.8% lower cost per use. Scenario modelling indicated that sterilizing handles as part of a hollowware set rather than as individual items would significantly reduce cost and carbon footprint. At both hospitals, associated clinical waste was essentially eliminated.

Conclusion

Judicious replacement of disposable covers with lightweight yet durable reusable handles can reduce costs, but increases carbon footprint in the current Australian energy context. Adopting predominantly renewable energy and more efficient sterilization practice would mitigate this.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Equipment ReuseOperating RoomsSterilizationCarbon FootprintDisposable EquipmentHumansAustraliaNew South Wales

Stichwörter der Autor:innen

carbon footprintlife‐cycle assessmentoperating theatrereusablesingle‐use

Autor:innen und Institutionen

  • Division of Surgery, John Hunter Hospital, Newcastle, New South Wales, Australia.
  • Clinical Lead in Surgery, NSW Ministry of Health Climate Risk and Net Zero Unit, St Leonards, New South Wales, Australia.
  • Wiser Healthcare, School of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.
  • Healthcare Carbon Lab, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Parkville, Victoria, Australia.
  • Healthy Environments and Lives (HEAL) Global Research Centre, Health Research Institute, Faculty of Health, University of Canberra, Canberra, Australian Capital Territory, Australia.

ORCID-Profile: Stanley Chen, Philomena Colagiuri, Kristen Pickles

Zitieren

APA

Chen, S., McAlister, S., Colagiuri, P., Pickles, K., & Barratt, A. L. (2025). Switching to reusable operating theatre equipment: lessons learnt from sterile light handle projects in two Australian hospitals. ANZ Journal of Surgery. https://doi.org/10.1111/ans.19306

Vancouver

Chen S, McAlister S, Colagiuri P, Pickles K, Barratt AL. Switching to reusable operating theatre equipment: lessons learnt from sterile light handle projects in two Australian hospitals. ANZ Journal of Surgery. 2025. doi:10.1111/ans.19306

BibTeX
@article{Chen2025,
  author = {Chen, Stanley and McAlister, Scott and Colagiuri, Philomena and Pickles, Kristen and Barratt, Alexandra L},
  title = {Switching to reusable operating theatre equipment: lessons learnt from sterile light handle projects in two Australian hospitals},
  journal = {ANZ Journal of Surgery},
  year = {2025},
  doi = {10.1111/ans.19306}
}
Kostenlos starten →