Comparison of Two High‐Power Ablation Strategies for Typical Atrial Flutter: Acute and Long‐Term Outcome
Annals of Noninvasive Electrocardiology · 2025
DOI: 10.1111/anec.70089 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Annals of Noninvasive Electrocardiology, 2025. Verfasst von Wael Zaher und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Centre Hospitalier EpiCURA, Hornu, Belgium. Hauptthemen laut MEDLINE: Atrial Flutter, Catheter Ablation. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Ablation of the cavo‐tricuspid isthmus (CTI) is the standard treatment for typical atrial flutter. High‐power strategies have been described to improve lesion efficacy and durability.
Objective
To compare the acute success, safety, and long‐term outcomes of two strategies of high‐power CTI ablation using 8‐mm gold‐tip nonirrigated and 4‐mm irrigated‐tip catheters.
Methods
This single‐center prospective cohort study included 253 patients who underwent CTI ablation. Patients were treated with either an 8‐mm gold‐tip nonirrigated catheter (60 W, ≥ 30 s) or a 4‐mm irrigated catheter (45 W, ≥ 30 s). Procedural outcomes, safety, and long‐term follow‐up data were assessed.
Results
Using a propensity score matching, 180 patients were yielded with a 1:1 ratio. Acute bidirectional CTI block was achieved in 97.8% of the 4‐mm group and 97.8% of the 8‐mm group ( p = 1.000). No major complications were reported. During a median follow‐up of 27.7 ± 20.1 months, freedom from atrial arrhythmia was 93.3% in both groups (log rank p value 0.935). No significant differences were observed in atrial fibrillation incidence, pacemaker implantation, or cardiovascular mortality between the groups.
Conclusion
High‐power CTI ablation with both 8‐mm gold‐tip nonirrigated and 4‐mm irrigated catheters is highly effective and safe, providing durable outcomes over long‐term follow‐up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Centre Hospitalier EpiCURA, Hornu, Belgium.
ORCID-Profile: Wael Zaher
Zitieren
APA
Zaher, W., Marcon, L., Ebinger, K. R., & Sorgente, A. (2025). Comparison of Two High‐Power Ablation Strategies for Typical Atrial Flutter: Acute and Long‐Term Outcome. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.70089
Vancouver
Zaher W, Marcon L, Ebinger KR, Sorgente A. Comparison of Two High‐Power Ablation Strategies for Typical Atrial Flutter: Acute and Long‐Term Outcome. Annals of Noninvasive Electrocardiology. 2025. doi:10.1111/anec.70089
BibTeX
@article{Zaher2025,
author = {Zaher, Wael and Marcon, Lorenzo and Ebinger, Klaus-Richard and Sorgente, Antonio},
title = {Comparison of Two High‐Power Ablation Strategies for Typical Atrial Flutter: Acute and Long‐Term Outcome},
journal = {Annals of Noninvasive Electrocardiology},
year = {2025},
doi = {10.1111/anec.70089}
}
EUVIMED