Identifying Demographic Factors Affecting the ECG Duration Collected Using a Single‐Lead ECG Patch Device
Annals of Noninvasive Electrocardiology · 2025
DOI: 10.1111/anec.70068 ↗Kurz gefasst
Klinische Studie in der Zeitschrift Annals of Noninvasive Electrocardiology, 2025. Verfasst von Dillon J Dzikowicz und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Nursing, University of Rochester, Rochester, New York, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Electrocardiography, Electrocardiography, Ambulatory. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, Home-based videoplethysmographic detection of atrial fibrillation.
Abstract (Originalsprache)
Introduction
Atrial fibrillation (AF), affecting 3% of the US adults, is the most common arrhythmia. While ambulatory electrocardiogram (ECG) monitoring is essential for AF detection, conventional technologies have diagnostic limitations due to AF's sporadic nature. ECG patches offer extended monitoring periods, though their effectiveness is primarily limited by deteriorating skin‐electrode contact rather than battery or memory constraints.
Objectives
This analysis reports our experience with the Zio ECG patch (iRhythm, San Francisco, CA) in 256 AF patients.
Method
We analyzed human and technical factors and their association with ECG recording duration using previously recorded data which employed the ECG patch as a reference. Descriptive statistics and logistic regression were used to identify associations.
Results
Body mass index (BMI) was found to be an independent predictor of poorer compliance in a dose‐dependent manner ( B = −0.046, OR = 0.955, 95% CI: 0.916–0.996, p = 0.033). Loss of adhesive was the primary reason for poor compliance ( n = 25; 11%). These findings can guide researchers and clinicians in determining the appropriateness of a 14‐day ECG patch based on expected wear time and patient compliance.
Conclusion
BMI significantly impacts ECG patch compliance, primarily through adhesive failures. These findings indicate the need for improved adhesive technologies for higher BMI patients. Future device development should prioritize maintaining electrode‐skin contact across diverse patient populations. Trial Registration ClinicalTrials.gov Identifier : NCT04267133
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Nursing, University of Rochester, Rochester, New York, USA.
- Clinical Cardiovascular Research Center, University of Rochester Medical Center, Rochester, New York, USA.
ORCID-Profile: Dillon J Dzikowicz
Förderung
- NHLBI NIH HHS
- Home-based videoplethysmographic detection of atrial fibrillation
Zitieren
APA
Dzikowicz, D. J., Aktas, M., Mykins, B., Xia, X., Zareba, W., & Couderc, J. P. (2025). Identifying Demographic Factors Affecting the ECG Duration Collected Using a Single‐Lead ECG Patch Device. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.70068
Vancouver
Dzikowicz DJ, Aktas M, Mykins B, Xia X, Zareba W, Couderc JP. Identifying Demographic Factors Affecting the ECG Duration Collected Using a Single‐Lead ECG Patch Device. Annals of Noninvasive Electrocardiology. 2025. doi:10.1111/anec.70068
BibTeX
@article{Dzikowicz2025,
author = {Dzikowicz, Dillon J and Aktas, Mehmed and Mykins, Betty and Xia, Xiaojuan and Zareba, Wojciech and Couderc, Jean-Phillippe},
title = {Identifying Demographic Factors Affecting the ECG Duration Collected Using a Single‐Lead ECG Patch Device},
journal = {Annals of Noninvasive Electrocardiology},
year = {2025},
doi = {10.1111/anec.70068}
}
EUVIMED