Examining the Effects of Different Exertion Levels and Reference Standards on the Diagnostic Accuracy of Exercise ECG for Detecting Coronary Artery Disease — A Pilot Study
Annals of Noninvasive Electrocardiology · 2025
DOI: 10.1111/anec.70042 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Noninvasive Electrocardiology, 2025. Verfasst von Julius Heimann und 3 weiteren Autor:innen. Beteiligte Einrichtung: Evangelisches Krankenhaus Duesseldorf, Dusseldorf, Germany. Hauptthemen laut MEDLINE: Coronary Artery Disease, Electrocardiography, Exercise Test, Sensitivity and Specificity. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Exercise electrocardiogram (ECG) is frequently used for evaluating patients with suspected coronary artery disease (CAD). However, it has been downgraded in international guidelines due to a limited sensitivity and specificity, compared with other non‐invasive tests.
Methods
We hypothesized, that a sufficient exertion going beyond 85% of the age predicted maximal heart rate (APMHR), by considering the achieved level of workload can improve sensitivity and specificity of the exercise ECG. Secondly, the performance of exercise ECG, when evaluated against a functional reference standard has barely been investigated, although an improved diagnostic accuracy has been reported for other non‐invasive tests in this case. Therefore, in this pilot study, a total of 147 patients without known CAD who underwent exercise ECG followed by coronary angiography within 90 days were retrospectively evaluated.
Results
The combined end point of 85% of APMHR and 75% of the predicted workload showed a slight but not statistically significant benefit over APMHR alone (66.7% vs. 58.1%; p = 0.545). The sensitivity of ST‐segment depression was 51.3% for detecting anatomically defined CAD and 62.5% for functionally relevant CAD ( p = 0.378).
Conclusions
Although the results of this pilot study lack statistical significance, the numeric differences clearly justify further research on this topic.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Evangelisches Krankenhaus Duesseldorf, Dusseldorf, Germany.
- University of Cologne, Faculty of Medicineand University Hospital Cologne, Cologne, Germany.
- Kliniken der Stadt Koeln, Koln, Germany.
- German Sport University Cologne, Koln, Germany.
ORCID-Profile: Julius Heimann, Christine Joisten
Zitieren
APA
Heimann, J., Schramm, T., Grauduszus, M., & Joisten, C. (2025). Examining the Effects of Different Exertion Levels and Reference Standards on the Diagnostic Accuracy of Exercise ECG for Detecting Coronary Artery Disease — A Pilot Study. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.70042
Vancouver
Heimann J, Schramm T, Grauduszus M, Joisten C. Examining the Effects of Different Exertion Levels and Reference Standards on the Diagnostic Accuracy of Exercise ECG for Detecting Coronary Artery Disease — A Pilot Study. Annals of Noninvasive Electrocardiology. 2025. doi:10.1111/anec.70042
BibTeX
@article{Heimann2025,
author = {Heimann, Julius and Schramm, Thomas and Grauduszus, Martin and Joisten, Christine},
title = {Examining the Effects of Different Exertion Levels and Reference Standards on the Diagnostic Accuracy of Exercise ECG for Detecting Coronary Artery Disease — A Pilot Study},
journal = {Annals of Noninvasive Electrocardiology},
year = {2025},
doi = {10.1111/anec.70042}
}
EUVIMED