EUVIMEDEUVIMED entdecken
BeobachtungsstudieVergleichsstudieOpen Access · CC BY 4.0

Computerized QT and QTc Measurements From Bedside ICU Monitors Are Similar to Those Derived From a Standard 12‐Lead ECG

Arthur Murray, Karolina Ho, Thomas J Hoffmann, Gopika K Ganesh, Shelvin Prasad, Sarah Berger, Cass Sandoval, Amy Larsen, Hildy Schell-Chaple, Michele M Pelter iD

Annals of Noninvasive Electrocardiology · 2025

DOI: 10.1111/anec.70031 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Annals of Noninvasive Electrocardiology, 2025. Verfasst von Arthur Murray und 9 weiteren Autor:innen. Beteiligte Einrichtung: Benioff Children's Hospital-Oakland, Oakland, California, USA. Hauptthemen laut MEDLINE: Electrocardiography, Intensive Care Units, Point-of-Care Systems. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of California San Fransicso.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

QT/QTc prolongation is associated with an increased risk for torsade de pointes. In at‐risk hospitalized patients, it is common to obtain a standard 12‐lead electrocardiogram (ECG) for this assessment, but this interrupts patient care. Our hospital recently introduced bedside monitors in the intensive care unit (ICU) with continuous QT/QTc software. However, only four of the seven available ECG leads are used.

Purpose

Evaluate the agreement between computerized QT/QTc measurements from the bedside monitor (four leads) and a time‐matched standard 12‐lead ECG.

Design

Prospective observational study in three adult ICUs.

Methods

QT/QTc measurements were obtained from a convenience sample, and the two ECG types were ≤ 30 min apart. Agreement was evaluated using Bland–Altman analysis.

Results

A total of 120 patients were evaluated for inclusion, and 60 (50%) had a 12‐lead ECG for comparison. The mean bias difference for QT measurements was not statistically different ( β = −2.47, 95% CI = 5.50 to −11.05; p = 0.44; limits of agreement (LOA) = −64.37 to 59.44). Similar non‐statistical differences were observed for QTc ( β = −3.20, 95% CI = 5.50 to −11.05; p = 0.44; LOA = −67.43 to 61.03).

Conclusion

There was good agreement for both QT and QTc measurements between the two methods. These pilot data are promising and suggest QT/QTc measurements from bedside monitors (four leads) may be an acceptable alternative to obtaining additional standard 12‐lead ECGs. Given that half of the ICU patients screened did not have a 12‐lead ECG recorded, bedside monitor QT/QTc's could identify at‐risk patients. However, an evaluation in a larger sample and non‐ICU patients is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyIntensive Care UnitsPoint-of-Care SystemsHumansMaleFemaleProspective StudiesMiddle AgedAgedReproducibility of ResultsLong QT Syndrome

Autor:innen und Institutionen

  • Benioff Children's Hospital-Oakland, Oakland, California, USA.
  • UCSF Health, University of California, San Francisco, California, USA.
  • Epidemiology and Biostatistics, School of Medicine and Office of Research, School of Nursing, University of California San Francisco, San Francisco, California, USA.
  • Kaiser Permanente, San Rafael, California, USA.
  • Adult Critical Care, UCSF Health, University of California, San Francisco, California, USA.
  • Center for Nursing Excellence & Innovation, UCSF Health, University of California San Francisco, San Francisco, California, USA.

ORCID-Profile: Michele M Pelter

Förderung

  • University of California San Fransicso

Zitieren

APA

Murray, A., Ho, K., Hoffmann, T. J., Ganesh, G. K., Prasad, S., Berger, S., Sandoval, C., Larsen, A., Schell-Chaple, H., & Pelter, M. M. (2025). Computerized QT and QTc Measurements From Bedside ICU Monitors Are Similar to Those Derived From a Standard 12‐Lead ECG. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.70031

Vancouver

Murray A, Ho K, Hoffmann TJ, Ganesh GK, Prasad S, Berger S, et al. Computerized QT and QTc Measurements From Bedside ICU Monitors Are Similar to Those Derived From a Standard 12‐Lead ECG. Annals of Noninvasive Electrocardiology. 2025. doi:10.1111/anec.70031

BibTeX
@article{Murray2025,
  author = {Murray, Arthur and Ho, Karolina and Hoffmann, Thomas J and Ganesh, Gopika K and Prasad, Shelvin and Berger, Sarah and Sandoval, Cass and Larsen, Amy and Schell-Chaple, Hildy and Pelter, Michele M},
  title = {Computerized QT and QTc Measurements From Bedside ICU Monitors Are Similar to Those Derived From a Standard 12‐Lead ECG},
  journal = {Annals of Noninvasive Electrocardiology},
  year = {2025},
  doi = {10.1111/anec.70031}
}
Kostenlos starten →