Fachartikel in der Zeitschrift Annals of Noninvasive Electrocardiology, 2024. Verfasst von Ning-Han Shi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Shandong First Medical University, Jinan, China. Hauptthemen laut MEDLINE: Echocardiography, Three-Dimensional, Echocardiography, Transesophageal, Mitral Valve Insufficiency, Balloon Valvuloplasty. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to investigate the structure of the mitral valve in patients undergoing mitral valvuloplasty (MVP) using real‐time three‐dimensional transesophageal echocardiography (RT‐3D‐TEE). The main objective was to study the relationship between intraoperative annuloplasty ring size and mitral valve structure dimensions, with a focus on exploring the application value of RT‐3D‐TEE in MVP.

Methods

A total of 28 patients with degenerative mitral regurgitation (DMR), who underwent MVP between February and September 2022, as well as 12 normal control cases, were enrolled in this study. The MV annulus and leaflets were quantitatively analyzed using MVN software.

Results

The DMR group exhibited significantly greater dimensions in various parameters of the mitral valve, including the anterolateral‐to‐posteromedial diameter ( D AlPm ), anterior‐to‐posterior diameter ( D AP ), annulus height ( H A ), three‐dimensional annulus circumference ( C A3D ), two‐dimensional annulus area ( AA 2D ), anterior leaflet area ( A ant ), posterior leaflet area ( A post ), anterior leaflet length ( L ant ), posterior leaflet length ( L post ), and tenting volume ( V tent ) compared to the control group.

Conclusion

Real‐time three‐dimensional transesophageal echocardiography provides valuable insights into the morphological structure of the mitral valve and lesion location. It can aid in surgical decision‐making, validate the success of MVP, and potentially reduce mortality and complications associated with mitral valve repair procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, Three-DimensionalEchocardiography, TransesophagealMitral Valve InsufficiencyBalloon ValvuloplastyHumansElectrocardiographyMitral Valve

Stichwörter der Autor:innen

annuloplasty ringmitral regurgitationmitral valve structuremitral valvuloplastyreal-time three-dimensional transesophageal echocardiography

Autor:innen und Institutionen

  • Shandong First Medical University, Jinan, China.
  • Department of Ultrasound, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China.
  • Department of Cardiovascular Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China.

ORCID-Profile: Mei Zhu

Zitieren

APA

Shi, N. H., Zhang, N., Zhang, S., Zhang, H. Z., Zou, C. W., & Zhu, M. (2024). Mitral valvuloplasty using real‐time three‐dimensional transesophageal echocardiography. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.13104

Vancouver

Shi NH, Zhang N, Zhang S, Zhang HZ, Zou CW, Zhu M. Mitral valvuloplasty using real‐time three‐dimensional transesophageal echocardiography. Annals of Noninvasive Electrocardiology. 2024. doi:10.1111/anec.13104

BibTeX
@article{Shi2024,
  author = {Shi, Ning-Han and Zhang, Nan and Zhang, Shuo and Zhang, Hai-Zhou and Zou, Cheng-Wei and Zhu, Mei},
  title = {Mitral valvuloplasty using real‐time three‐dimensional transesophageal echocardiography},
  journal = {Annals of Noninvasive Electrocardiology},
  year = {2024},
  doi = {10.1111/anec.13104}
}
Kostenlos starten →