EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing

Xianchao Sun iD, Yue Huang iD

Annals of Noninvasive Electrocardiology · 2023

DOI: 10.1111/anec.13042 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Annals of Noninvasive Electrocardiology, 2023. Verfasst von Xianchao Sun und 1 weiteren Autor:innen. Beteiligte Einrichtung: First Hospital of Jiaxing, Zhejiang, China. Hauptthemen laut MEDLINE: Atrial Fibrillation, Defibrillators, Implantable, Tachycardia, Supraventricular, Tachycardia, Ventricular. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The combined use of an implantable cardioverter defibrillator (ICD) and His bundle pacing (HBP) is believed to benefit patients with dilated cardiomyopathy (DCM) and atrial fibrillation but needs more guidance built on clinical experience. A patient who had an implanted dual‐chamber ICD with HBP presented to our hospital with DCM and atrial fibrillation. In the present case, the criteria for differential diagnosis were set as “if all,” which requires matching the morphological template, sudden onset, and interval stability. Ventricular tachycardia (VT) was misdiagnosed as supraventricular tachycardia due to morphological matching to sinus tachycardia. The misdiagnosis and mistaken VT treatment(ICD adaptive treatment) highlight the importance of personalized settings for differential diagnosis to avoid such a misdiagnosis or omission.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationDefibrillators, ImplantableTachycardia, SupraventricularTachycardia, VentricularHumansBundle of HisElectrocardiography

Stichwörter der Autor:innen

His bundle packingatrial fibrillationimplantable cardioverter defibrillatorsupraventricular tachycardiaventricular tachycardia

Autor:innen und Institutionen

  • First Hospital of Jiaxing, Zhejiang, China.

ORCID-Profile: Xianchao Sun, Yue Huang

Zitieren

APA

Sun, X., & Huang, Y. (2023). A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.13042

Vancouver

Sun X, Huang Y. A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing. Annals of Noninvasive Electrocardiology. 2023. doi:10.1111/anec.13042

BibTeX
@article{Sun2023,
  author = {Sun, Xianchao and Huang, Yue},
  title = {A case of supraventricular tachycardia misdiagnosis after dual‐chamber implantable cardioverter defibrillator implantation with His bundle pacing},
  journal = {Annals of Noninvasive Electrocardiology},
  year = {2023},
  doi = {10.1111/anec.13042}
}
Kostenlos starten →