Fachartikel in der Zeitschrift Annals of Noninvasive Electrocardiology, online erschienen am 24.10.2021. Verfasst von Mhd Khalil Tamr Agha und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary and Sleep Medicine, Department of Pediatrics, Children's Mercy Kansas City, Kansas City, Missouri, USA. Hauptthemen laut MEDLINE: Electrocardiography, Ambulatory, Long QT Syndrome. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
QT interval represents the ventricular depolarization and repolarization. Its accurate measurement is critical since prolonged QT can lead to sudden cardiac death. QT is affected by heart rate and is corrected to QTc via several formulae. QTc is commonly calculated on the ECG and not the 24‐h Holter.
Methods
100 patients presenting to our institution were evaluated by an ECG followed by a 24‐h Holter. QTc measurement on both platforms using Bazett and Fridericia formulae was recorded and compared.
Results
Mean age was 14.09 years, with the majority being males. Mean heart rate was 125.87. In the ECG, the mean QTc interval via the Bazett formula was 0.40 s compared with 0.38 s using the Fridericia formula. The mean corrected QT via the Bazett formula was 0.45, 0.39, and 0.42 s for the shortest RR, the longest RR, and the average RR, respectively. In contrast to the Fridericia formula, the corrected QT interval was 0.40, 0.39, and 0.40 s for the shortest RR, the longest RR, and the average RR, respectively. Using the Bazett formula, the highest specificity was reached during the longest RR interval (92.2%), while the highest sensitivity was recorded during the shortest RR interval (40%). As for the Fridericiaformula, sensitivity always reached 0%, while the highest specificity was reached during the average RR interval.
Conclusion
QTc measured during Holter ECG reached a high specificity regardless of RR interval using the Fridericia and during the longest and the average RR interval for the Bazett formula. The consistently low sensitivity reveals that Holter ECG should not be used to rule out prolonged QT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Pulmonary and Sleep Medicine, Department of Pediatrics, Children's Mercy Kansas City, Kansas City, Missouri, USA.
- Division of Cardiology, Department of Pediatrics and Adolescent Medicine, American University of Beirut Medical Center, Beirut, Lebanon.
- Department of Family Medicine, American University of Beirut Medical Center, Beirut, Lebanon.
- Division of Cardiology, Department of Internal Medicine, American University of Beirut Medical Center, Beirut, Lebanon.
ORCID-Profile: Mariam Arabi
Zitieren
APA
Tamr Agha, M. K., Fakhri, G., Ahmed, M., El Sedawy, O., Abi Saleh, B., Bitar, F., & Arabi, M. (2022). QTc interval on 24‐hour holter monitor: To trust or not to trust?. Annals of Noninvasive Electrocardiology, 27(1). https://doi.org/10.1111/anec.12899
Vancouver
Tamr Agha MK, Fakhri G, Ahmed M, El Sedawy O, Abi Saleh B, Bitar F, et al. QTc interval on 24‐hour holter monitor: To trust or not to trust?. Annals of Noninvasive Electrocardiology. 2022;27(1). doi:10.1111/anec.12899
BibTeX
@article{TamrAgha2022,
author = {Tamr Agha, Mhd Khalil and Fakhri, Ghina and Ahmed, Mohamed and El Sedawy, Omar and Abi Saleh, Bernard and Bitar, Fadi and Arabi, Mariam},
title = {QTc interval on 24‐hour holter monitor: To trust or not to trust?},
journal = {Annals of Noninvasive Electrocardiology},
year = {2022},
volume = {27},
number = {1},
doi = {10.1111/anec.12899}
}
EUVIMED