EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Artificial intelligence‐assisted tracheal intubation in humans: a prospective observational study of diagnostic accuracy

Alexander Fuchs iD, Aline Raeber, Ricarda Lippuner, Lea Weber, Yevheniia Borysenko, Markus Huber, Robert Greif iD, Thomas Riva iD

Anaesthesia · 2026

DOI: 10.1111/anae.70063 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Anaesthesia, 2026. Verfasst von Alexander Fuchs und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, Bern, Switzerland. Hauptthemen laut MEDLINE: Intubation, Intratracheal, Artificial Intelligence. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Innosuisse - Schweizerische Agentur för Innovationsförderung, Innosuisse - Schweizerische Agentur für Innovationsförderung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction larynGuide™ is a novel assistive software integrated with the C‐MAC ® videolaryngoscope, which provides guidance during laryngoscopy and advises on tracheal tube position. This first in‐human study evaluated the accuracy and reliability of larynGuide compared with the judgment of the airway operator.

Methods

This prospective, single‐centre, investigator‐initiated, observational study included adult patients undergoing elective surgery requiring general anaesthesia with tracheal intubation. After informed consent and standardised induction of anaesthesia, laryngoscopy and tracheal intubation were performed with a C‐MAC ® videolaryngoscope with a Macintosh blade by a board‐certified anaesthetist. larynGuide ran on a second screen, visible only to the study team but blinded to the airway operator. After tracheal intubation attempts, the airway operator confirmed tracheal tube placement visually and with capnography. The primary outcome was the real‐time accuracy of larynGuide in identifying correct tracheal tube placement.

Results

We enrolled 132 patients, of whom 110 were analysed. Of 108 patients with correctly placed tracheal tubes, larynGuide identified 102 (sensitivity 0.94, 95%CI 0.88–0.98). In six patients, the software misclassified tracheal tube position: two false negatives (i.e. the software advised a failed tracheal intubation despite correct placement); and four patients with no feedback. Among two patients with unsuccessful tracheal intubation due to oesophageal tube placement at the first attempt, larynGuide detected one.

Discussion

This first in‐human study has established the feasibility of AI‐guided real‐time tracheal intubation using larynGuide. The software showed promising sensitivity, while specificity was limited. Videolaryngoscopy image quality issues, including fogging and poor visibility, impaired the performance of the software.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intubation, IntratrachealArtificial IntelligenceHumansProspective StudiesFemaleMaleMiddle AgedLaryngoscopyAdultReproducibility of ResultsAgedAnesthesia, GeneralSoftwareLaryngoscopesSensitivity and SpecificityCapnography

Stichwörter der Autor:innen

airway managementartificial intelligencetracheal intubationvideolaryngoscopy

Autor:innen und Institutionen

  • Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, Bern, Switzerland.
  • Medical Faculty, University of Bern, Bern, Switzerland.

ORCID-Profile: Alexander Fuchs, Robert Greif, Thomas Riva

Förderung

  • Innosuisse - Schweizerische Agentur för Innovationsförderung
  • Innosuisse - Schweizerische Agentur für Innovationsförderung

Zitieren

APA

Fuchs, A., Raeber, A., Lippuner, R., Weber, L., Borysenko, Y., Huber, M., Greif, R., & Riva, T. (2026). Artificial intelligence‐assisted tracheal intubation in humans: a prospective observational study of diagnostic accuracy. Anaesthesia. https://doi.org/10.1111/anae.70063

Vancouver

Fuchs A, Raeber A, Lippuner R, Weber L, Borysenko Y, Huber M, et al. Artificial intelligence‐assisted tracheal intubation in humans: a prospective observational study of diagnostic accuracy. Anaesthesia. 2026. doi:10.1111/anae.70063

BibTeX
@article{Fuchs2026,
  author = {Fuchs, Alexander and Raeber, Aline and Lippuner, Ricarda and Weber, Lea and Borysenko, Yevheniia and Huber, Markus and Greif, Robert and Riva, Thomas},
  title = {Artificial intelligence‐assisted tracheal intubation in humans: a prospective observational study of diagnostic accuracy},
  journal = {Anaesthesia},
  year = {2026},
  doi = {10.1111/anae.70063}
}
Kostenlos starten →