EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY-NC-ND 4.0

Evaluation of the i‐gel® Plus supraglottic airway device in elective surgery: a prospective international multicentre study*

Jakub Werner, Olga Klementova, Jan Bruthans, Jaromir Macoun, Tomasz Gaszynski, Tomas Henlin, Will Donaldson, Erik Lichnovsky, Shiva Arava, Ana M Lopez, Raquel Berge, Pavel Michalek iD

Anaesthesia · 2024-12 · 79 (12) · 1284-1291

DOI: 10.1111/anae.16401 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Anaesthesia, online erschienen am 07.08.2024. Verfasst von Jakub Werner und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesia and Intensive Medicine, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic. Hauptthemen laut MEDLINE: Elective Surgical Procedures, Laryngeal Masks, Intubation, Intratracheal. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministerstvo Zdravotnictví Ceské Republiky.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The i‐gel® Plus is a modified version of the i‐gel® supraglottic airway device. It contains a wider drainage port; a longer tip; ramps inside the breathing channel; and an additional port for oxygen delivery. There has been no prospective evaluation of this device in clinical practice.

Methods

This international, multicentre, prospective cohort study aimed to evaluate the performance of the i‐gel Plus in adult patients undergoing elective procedures under general anaesthesia. The primary outcome was overall insertion success rate, defined as the ability to provide effective airway management through the device from insertion until the end of the surgical procedure. Secondary outcomes included device performance and incidence of postoperative adverse events. Data from the first 1000 patients are reported.

Results

In total, 1012 patients were enrolled; 12 forms were excluded from the final analysis due to incomplete data leaving 1000 included patients (545 female). Overall insertion success rate was 98.6%, with a first‐attempt success rate of insertion of 88.2%. A significant difference between females and males was seen for the overall success rate (97.4% vs. 99.6% respectively) but not for first‐attempt successful insertion. Mean (SD) oropharyngeal seal pressure was 32 (7) cmH 2 O. The only independent factor that increased the risk of first‐attempt failure was low operator experience. Complications included desaturation < 85% in 0.6%; traces of blood on the device in 7.4%; laryngospasm in 0.5%; and gastric contents inside the bowl in 0.2% of patients.

Conclusions

The i‐gel Plus appears to be an effective supraglottic airway device that is associated with a high insertion success rate and a reasonably low incidence of complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elective Surgical ProceduresLaryngeal MasksIntubation, IntratrachealHumansMaleFemaleProspective StudiesMiddle AgedAgedAdultEquipment DesignAirway ManagementCohort StudiesAnesthesia, GeneralPostoperative Complications

Stichwörter der Autor:innen

elective surgeryi‐gel® Plusoropharyngeal seal pressuresupraglottic airway device

Autor:innen und Institutionen

  • Department of Anaesthesia and Intensive Medicine, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic.
  • Masaryk University, Brno, Czech Republic.
  • Department of Anaesthesiology and Intensive Care Medicine, University Hospital Olomouc, Olomouc, Czech Republic.
  • Department of Anaesthesiology and Intensive Medicine, General University Hospital and First Medical Faculty of the Charles University, Prague, Czech Republic.
  • Department of Anaesthesiology and Intensive Therapy, Medical University of Lodz, Lodz, Poland.
  • Department of Anaesthesia and Intensive Medicine, Military University Hospital, Prague, Czech Republic.

ORCID-Profile: Pavel Michalek

Förderung

  • Ministerstvo Zdravotnictví Ceské Republiky

Zitieren

APA

Werner, J., Klementova, O., Bruthans, J., Macoun, J., Gaszynski, T., Henlin, T., Donaldson, W., Lichnovsky, E., Arava, S., Lopez, A. M., Berge, R., & Michalek, P. (2024). Evaluation of the i‐gel® Plus supraglottic airway device in elective surgery: a prospective international multicentre study*. Anaesthesia, 79(12), 1284-1291. https://doi.org/10.1111/anae.16401

Vancouver

Werner J, Klementova O, Bruthans J, Macoun J, Gaszynski T, Henlin T, et al. Evaluation of the i‐gel® Plus supraglottic airway device in elective surgery: a prospective international multicentre study*. Anaesthesia. 2024;79(12):1284-1291. doi:10.1111/anae.16401

BibTeX
@article{Werner2024,
  author = {Werner, Jakub and Klementova, Olga and Bruthans, Jan and Macoun, Jaromir and Gaszynski, Tomasz and Henlin, Tomas and Donaldson, Will and Lichnovsky, Erik and Arava, Shiva and Lopez, Ana M and Berge, Raquel and Michalek, Pavel},
  title = {Evaluation of the i‐gel® Plus supraglottic airway device in elective surgery: a prospective international multicentre study*},
  journal = {Anaesthesia},
  year = {2024},
  volume = {79},
  number = {12},
  pages = {1284--1291},
  doi = {10.1111/anae.16401}
}
Kostenlos starten →