EUVIMEDEUVIMED entdecken
Crossref

The effect of placement and management of intrathecal catheters following accidental dural puncture on the incidence of postdural puncture headache and severity: a retrospective real‐world study

Y Binyamin iD, Karam Azem, M Heesen, I Gruzman, A Frenkel, S Fein, L A Eidelman, A Garren, D Frank, S Orbach-Zinger

Anaesthesia · 2023

DOI: 10.1111/anae.16088 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Anaesthesia, 2023. Verfasst von Y Binyamin und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesia, Soroka University Medical Center and the Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israe…. Hauptthemen laut MEDLINE: Post-Dural Puncture Headache. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accidental dural puncture during an attempt to establish labour epidural analgesia can result in postdural puncture headache and long‐term debilitating conditions. Epidural blood patch, the gold standard treatment for this headache, is invasive and not always successful. Inserting an intrathecal catheter after accidental dural puncture may prevent postdural puncture headache. We evaluated the effect of intrathecal catheter insertion on the incidence of postdural puncture headache and the need for epidural blood patch and whether duration of intrathecal catheterisation or injection of intrathecal saline affected outcome. Our retrospective study was conducted at two tertiary, university‐affiliated medical centres between 2017 and 2022 and included 92,651 epidurals and 550 cases of accidental dural puncture (0.59%); 219 parturients (39.8%) received an intrathecal catheter and 331 (60.2%) a resited epidural. Use of an intrathecal catheter versus resiting the epidural did not decrease the odds of postdural puncture headache, adjusted odds ratio (aOR) (95%CI) 0.91 (0.81–1.01), but was associated with a lower need for epidural blood patch (aOR (95%CI) 0.82 (0.73–0.91), p < 0.001). We found no benefit in leaving in the intrathecal catheter for 24 h postpartum (postdural puncture headache, aOR (95%CI) 1.01 (1.00–1.02), p = 0.015; epidural blood patch, aOR (95%CI) 1.00 (0.99–1.01), p = 0.40). We found an added benefit of injecting intrathecal saline as it decreased the incidence of postdural puncture headache (aOR (95%CI) 0.85 (0.73–0.99), p = 0.04) and the need for epidural blood patch (aOR (95%CI) 0.75 (0.64–0.87), p < 0.001). Our study confirms the benefits of intrathecal catheterisation and provides guidance on how to best manage an intrathecal catheter.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Post-Dural Puncture HeadacheFemaleHumansRetrospective StudiesIncidencePuncturesCatheterizationBlood Patch, EpiduralCatheters

Stichwörter der Autor:innen

accidental dural punctureepidural blood patchlabour analgesianeuraxial analgesiapostdural puncture headache

Autor:innen und Institutionen

  • Department of Anaesthesia, Soroka University Medical Center and the Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel.
  • Department of Anaesthesia, Beilinson Hospital, Rabin Medical Center Associated with Sackler Medical School, Tel Aviv University, Tel Aviv, Israel.
  • Department of Anaesthesia, Kantonsspital Baden, Baden, Switzerland.
  • Department of Anaesthesia, Assuta Medical Center, Ashdod, Israel.
  • Columbia University, New York, NY, USA.

ORCID-Profile: Y Binyamin

Zitieren

APA

Binyamin, Y., Azem, K., Heesen, M., Gruzman, I., Frenkel, A., Fein, S., Eidelman, L. A., Garren, A., Frank, D., & Orbach-Zinger, S. (2023). The effect of placement and management of intrathecal catheters following accidental dural puncture on the incidence of postdural puncture headache and severity: a retrospective real‐world study. Anaesthesia. https://doi.org/10.1111/anae.16088

Vancouver

Binyamin Y, Azem K, Heesen M, Gruzman I, Frenkel A, Fein S, et al. The effect of placement and management of intrathecal catheters following accidental dural puncture on the incidence of postdural puncture headache and severity: a retrospective real‐world study. Anaesthesia. 2023. doi:10.1111/anae.16088

BibTeX
@article{Binyamin2023,
  author = {Binyamin, Y and Azem, Karam and Heesen, M and Gruzman, I and Frenkel, A and Fein, S and Eidelman, L A and Garren, A and Frank, D and Orbach-Zinger, S},
  title = {The effect of placement and management of intrathecal catheters following accidental dural puncture on the incidence of postdural puncture headache and severity: a retrospective real‐world study},
  journal = {Anaesthesia},
  year = {2023},
  doi = {10.1111/anae.16088}
}
Kostenlos starten →