Sharpening PUMA 's teeth: improving guidance for capnography to confirm tracheal intubation in cardiopulmonary resuscitation
Anaesthesia · 2023
DOI: 10.1111/anae.16002 ↗Kurz gefasst
Editorial in der Zeitschrift Anaesthesia, 2023. Verfasst von T Qureshi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Nuffield Department of Anaesthesia, Oxford University Hospitals NHS Foundation Trust, Oxford, UK. Hauptthemen laut MEDLINE: Capnography, Cardiopulmonary Resuscitation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Themen: Reanimation
Abstract (Originalsprache)
The principle that using waveform capnography is essential to confirm correct tracheal tube placement dates from the 1980s [1], and its mandatory use has been repeated in successive minimum monitoring guidelines [2]. It is nothing new to say that capnography supersedes all other clinical signs and that, in the absence of a characteristic end-tidal carbon dioxide (ETCO2) waveform, rare and trivial exceptions notwithstanding, the tube must be regarded as non-tracheal. Some cases of unrecognised oesophageal intubation highlighted theneed toextend thisprinciple to cardiopulmonary resuscitation (CPR), where it had been wrongly assumed that cardiac arrest would invariably result in a flat waveform making capnography useless, but this is not the case. The `no trace, wrongplace ́ campaignwas institutedpredominantlywithCPR in mind [3]. Evenmore recently, it transpired that,despite capnography being applied in a patient with a spontaneous circulation and there being no difficulties in airwaymanagement, oesophageal intubation still went undetected, mainly due to organisational and human factors issues [4]. As a result, international airway management societies have together issued the authoritative PUMA (Project for Universal Management of Airways) guidance to reinforce some well-established messages [5], and to add some important new recommendations, which include encouraging videolaryngoscopy as routine; verbalising the intubation steps to enhance team communication and specifically regarding an ETCO2 value > 1 kPa over at least seven breaths as confirmation of tracheal placement. In this last respect, `no trace, wrong place ́ has officially become `low or no trace,wrongplace ́. All this should be uncontroversial in the context of a patient with a spontaneous circulation such as during routine induction of anaesthesia, and PUMA has reemphasised some important principles. However, PUMA’s recommendations in the context of cardiac arrest retain some ambiguity that have important, perhaps unintended, consequences for clinical practice, and so would benefit from sharper definition, aswe explain below.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Nuffield Department of Anaesthesia, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
- University of Birmingham, UK.
- Guy's and St Thomas' NHS Foundation Trust (Heart, Lung and Critical Care Clinical Group), London, UK.
- University of Oxford, UK.
Zitieren
APA
Qureshi, T., Hutton, P., & Pandit, J. J. (2023). Sharpening PUMA 's teeth: improving guidance for capnography to confirm tracheal intubation in cardiopulmonary resuscitation. Anaesthesia. https://doi.org/10.1111/anae.16002
Vancouver
Qureshi T, Hutton P, Pandit JJ. Sharpening PUMA 's teeth: improving guidance for capnography to confirm tracheal intubation in cardiopulmonary resuscitation. Anaesthesia. 2023. doi:10.1111/anae.16002
BibTeX
@article{Qureshi2023,
author = {Qureshi, T and Hutton, P and Pandit, J J},
title = {Sharpening PUMA 's teeth: improving guidance for capnography to confirm tracheal intubation in cardiopulmonary resuscitation},
journal = {Anaesthesia},
year = {2023},
doi = {10.1111/anae.16002}
}
EUVIMED