EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Comparing Sperm Selection Tools to Improve DNA Integrity

Ashleigh Smith iD, Sonia Badrak, Josephine Pinto, Karolina Alichniewicz, Clare Boothroyd iD

Australian and New Zealand Journal of Obstetrics and Gynaecology · 2026-04 · 66 (2)

DOI: 10.1111/ajo.70095 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Australian and New Zealand Journal of Obstetrics and Gynaecology, online erschienen am 26.03.2026. Verfasst von Ashleigh Smith und 4 weiteren Autor:innen. Beteiligte Einrichtung: Consultant (Fertility specialist), Brisbane, Australia. Hauptthemen laut MEDLINE: Spermatozoa, DNA Fragmentation, Cell Separation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Sperm selection tools are used in assisted reproduction to isolate spermatozoa with the least DNA fragmentation (DF) to optimize fertilization, improve pregnancy outcome and reduce genetic abnormalities in the offspring.

Aims

This study aims to compare the sperm DF after three different sperm selection tools were performed on split samples from the neat (unprocessed, control) semen sample. (1) Density gradient centrifugation (DGC). (2) Density gradient centrifugation with swim‐up (DGC + swim‐up). (3) Microfluidic chip (ZyMot). The primary outcome was the DF of spermatozoa after sperm selection tool as measured by Halosperm test. Scientific time taken to perform the test and the cost of consumables were recorded. Materials and Methods This was a prospective assessor blinded controlled trial between split semen samples conducted at Care Fertility (Australia) in 2024/2025 to compare DF after sperm selection. For each sample, a routine semen analysis was performed, and residual sample was split for processing by sperm selection tools.

Results

Thirty participants consented and underwent the trial. Neat (control) semen: mean sperm DF = 9.5% DGC: mean sperm DF = 4.83% AUD34.11 consumables + 60 min scientific time. DGC+Swim‐up: mean sperm DF = 1.8% AUD34.73 consumables + 90 min scientific time. Microfluidic Chip mean sperm DF = 0.06% AUD143.46 consumables + 30 min scientific time.

Conclusions

Microfluidic chip is highly effective at selecting sperm with the least DF and is faster to perform than DGC +/− Swim up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SpermatozoaDNA FragmentationCell SeparationHumansMaleSemen AnalysisProspective StudiesCentrifugation, Density GradientSperm Motility

Autor:innen und Institutionen

  • Consultant (Fertility specialist), Brisbane, Australia.
  • Care Fertility, Greenslopes, Queensland, Australia.
  • Care Fertility, Greenslopes Hospital, Greenslopes, Queensland, Australia.

ORCID-Profile: Ashleigh Smith, Clare Boothroyd

Zitieren

APA

Smith, A., Badrak, S., Pinto, J., Alichniewicz, K., & Boothroyd, C. (2026). Comparing Sperm Selection Tools to Improve DNA Integrity. Australian and New Zealand Journal of Obstetrics and Gynaecology, 66(2). https://doi.org/10.1111/ajo.70095

Vancouver

Smith A, Badrak S, Pinto J, Alichniewicz K, Boothroyd C. Comparing Sperm Selection Tools to Improve DNA Integrity. Australian and New Zealand Journal of Obstetrics and Gynaecology. 2026;66(2). doi:10.1111/ajo.70095

BibTeX
@article{Smith2026,
  author = {Smith, Ashleigh and Badrak, Sonia and Pinto, Josephine and Alichniewicz, Karolina and Boothroyd, Clare},
  title = {Comparing Sperm Selection Tools to Improve DNA Integrity},
  journal = {Australian and New Zealand Journal of Obstetrics and Gynaecology},
  year = {2026},
  volume = {66},
  number = {2},
  doi = {10.1111/ajo.70095}
}
Kostenlos starten →