Comparison of craniometric measurements of New Zealand rabbit ( Oryctolagus cuniculus L.) using three‐dimensional scanner with digital calliper measurements: A methodological study
Anatomia, Histologia, Embryologia · 2024
DOI: 10.1111/ahe.13023 ↗Kurz gefasst
Fachartikel in der Zeitschrift Anatomia, Histologia, Embryologia, 2024. Verfasst von Ali Koçyiğit und 1 weiteren Autor:innen. Beteiligte Einrichtung: Harran University Laboratory and Veterinary Health Vocational School, Birecik, Sanliurfa, Turkey. Hauptthemen laut MEDLINE: Skull, Foramen Magnum. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
As technology has developed in recent years, the use of three‐dimensional (3D) scanners and printers has become widespread in the medical field. However, since this field is new, all kinds of methodological and experimental related studies gain importance. This study aimed to identify the differences between the calliper measurements by determining the craniometric data on the models constructed by scanning the crania of New Zealand Rabbits ( Oryctolagus cuniculus L.), preferred as experimental animals, with a three‐dimensional scanner. Therefore, a total of 12 New Zealand rabbits including 6 females and 6 males were used. After the crania that comprised the study material were macerated, they were subjected to 3D scanning. After the scanning process was completed, they were craniometrically measured both on the scanned models and by using a digital calliper. Analysis of the craniometric data of the 3D scanner showed that there was a difference between sexes at the level of p < 0.05 in widest length between the external acoustic meatus (WLBEAM), skull width and Foramen magnum height (FMH) parameters and cranial index data, and at the level of p < 0.001 in the largest nasal width (LNW) parameter. A statistical difference was found between sexes in frontal length, WLBEAM, LNW and FMH parameters and cranial index values in craniometric data collected with the digital calliper ( p < 0.05). Consequently, the data collected in this study were found to be close to each other in both methods, suggesting that the 3D scanner may be used in morphometric studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Harran University Laboratory and Veterinary Health Vocational School, Birecik, Sanliurfa, Turkey.
- Department of Anatomy, Faculty of Veterinary Medicine, Harran University, Sanliurfa, Turkey.
ORCID-Profile: Ali Koçyiğit, İsmail Demircioğlu
Zitieren
APA
Koçyiğit, A., & Demircioğlu, İ. (2024). Comparison of craniometric measurements of New Zealand rabbit ( Oryctolagus cuniculus L.) using three‐dimensional scanner with digital calliper measurements: A methodological study. Anatomia, Histologia, Embryologia. https://doi.org/10.1111/ahe.13023
Vancouver
Koçyiğit A, Demircioğlu İ. Comparison of craniometric measurements of New Zealand rabbit ( Oryctolagus cuniculus L.) using three‐dimensional scanner with digital calliper measurements: A methodological study. Anatomia, Histologia, Embryologia. 2024. doi:10.1111/ahe.13023
BibTeX
@article{Koyiit2024,
author = {Koçyiğit, Ali and Demircioğlu, İsmail},
title = {Comparison of craniometric measurements of New Zealand rabbit ( Oryctolagus cuniculus L.) using three‐dimensional scanner with digital calliper measurements: A methodological study},
journal = {Anatomia, Histologia, Embryologia},
year = {2024},
doi = {10.1111/ahe.13023}
}
EUVIMED