Robust imaging approach for precise prediction of postoperative lung function in lung cancer patients prior to curative operation
Thoracic Cancer · 2024
DOI: 10.1111/1759-7714.15153 ↗Kurz gefasst
Fachartikel in der Zeitschrift Thoracic Cancer, 2024. Verfasst von Suho Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea. Hauptthemen laut MEDLINE: Lung Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Institute for Information and Communications Technology Promotion Artificial Intelligence Innovation, National Research Foundation of Korea.
Themen: Onkologische Pflege
Abstract (Originalsprache)
Background
To create a combined variable integrating both ventilation and perfusion as measured by preoperative dual‐energy computed tomography (DECT), compare the results with predicted postoperative (PPO) lung function as estimated using conventional methods, and assess agreement with actual postoperative lung function.
Methods
A total of 33 patients with lung cancer who underwent curative surgery after DECT and perfusion scan were selected. Ventilation and perfusion values were generated from DECT data. In the “combined variable method,” these two variables and clinical variables were linearly regressed to estimate PPO lung function. Six PPO lung function parameters (segment counting, perfusion scan, volume analysis, ventilation map, perfusion map, and combined variable) were compared with actual postoperative lung function using an intraclass correlation coefficient (ICC).
Results
The segment counting method produced the highest ICC for forced vital capacity (FVC) at 0.93 ( p < 0.05), while the segment counting and perfusion map methods produced the highest ICC for forced expiratory volume in 1 second (FEV 1 ; both 0.89, p < 0.05). The highest ICC value when using the combined variable method was for FEV 1 /FVC (0.75, p < 0.05) and diffusing capacity of the lung for carbon monoxide (DLco; 0.80, p < 0.05) when using the perfusion map method. Overall, the perfusion map and ventilation map provided the best performance, followed by volume analysis, segment counting, perfusion scan, and the combined variable.
Conclusions
Use of DECT image processing to predict postoperative lung function produced better agreement with actual postoperative lung function than conventional methods. The combined variable method produced ICC values of 0.8 or greater for FVC and FEV 1 .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
- Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, South Korea.
ORCID-Profile: You Jin Oh, Ho Yun Lee
Förderung
- Institute for Information and Communications Technology Promotion Artificial Intelligence Innovation
- National Research Foundation of Korea
Zitieren
APA
Kim, S., Kim, J., Jeong, U., Oh, Y. J., Park, S. G., & Lee, H. Y. (2024). Robust imaging approach for precise prediction of postoperative lung function in lung cancer patients prior to curative operation. Thoracic Cancer. https://doi.org/10.1111/1759-7714.15153
Vancouver
Kim S, Kim J, Jeong U, Oh YJ, Park SG, Lee HY. Robust imaging approach for precise prediction of postoperative lung function in lung cancer patients prior to curative operation. Thoracic Cancer. 2024. doi:10.1111/1759-7714.15153
BibTeX
@article{Kim2024,
author = {Kim, Suho and Kim, Jonghoon and Jeong, Uichan and Oh, You Jin and Park, Sung Goo and Lee, Ho Yun},
title = {Robust imaging approach for precise prediction of postoperative lung function in lung cancer patients prior to curative operation},
journal = {Thoracic Cancer},
year = {2024},
doi = {10.1111/1759-7714.15153}
}
EUVIMED