EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Surveillance of influenza A and B viruses from community and hospital wastewater treatment plants

Sneka Panneerselvam, Athira Manayan Parambil, Anup Jayaram, Prasad Varamballi, Chiranjay Mukhopadhyay, Anitha Jagadesh iD

Environmental Microbiology Reports · 2024-08 · 16 (4)

DOI: 10.1111/1758-2229.13317 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Microbiology Reports, online erschienen am 22.08.2024. Verfasst von Sneka Panneerselvam und 5 weiteren Autor:innen. Beteiligte Einrichtung: Manipal Institute of Virology, Manipal Academy of Higher Education, Manipal, India. Hauptthemen laut MEDLINE: Wastewater, Influenza A virus, Influenza B virus, Influenza, Human. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Manipal Institute of Virology, Manipal Academy of Higher Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Influenza virus is a well‐known pathogen that can cause epidemics and pandemics. Several surveillance methods are being followed to monitor the transmission patterns and spread of influenza in the community. Wastewater‐based Epidemiology (WBE) can serve as an additional tool to detect the presence of influenza viruses. The current study primarily focuses on surveillance of Influenza A and Influenza B in wastewater treatment plant (WWTP) samples. A total of 100 wastewater samples were collected in July ( n = 50) and August ( n = 50) 2023 from four different WWTPs in Manipal and Udupi, district of Karnataka, India. The WWTP samples were processed and tested by Real‐Time reverse transcriptase PCR (RT‐PCR). The data generated was analysed in comparison with the clinical Influenza cases. Of the 100 samples, 18 (18%) tested positive for Influenza A virus and 2 (2%) tested positive for Influenza B virus, with a viral load ranging 1.4 x 10 2 –2.2 x 10 3 gc/L for influenza A virus and 5.2 x 10 3 –7.7 x 10 3 gc/L for influenza B virus. On correlating the WWTP positivity with clinical case, it was found that influenza clinical cases and virus positivity in wastewater increased simultaneously, emphasizing WBE as a concurrent method for monitoring influenza virus activity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WastewaterInfluenza A virusInfluenza B virusInfluenza, HumanWastewater-Based Epidemiological MonitoringHumansIndiaReal-Time Polymerase Chain ReactionViral LoadPrevalence

Substanzen

Wastewater

Autor:innen und Institutionen

  • Manipal Institute of Virology, Manipal Academy of Higher Education, Manipal, India.

ORCID-Profile: Anitha Jagadesh

Förderung

  • Manipal Institute of Virology, Manipal Academy of Higher Education

Zitieren

APA

Panneerselvam, S., Manayan Parambil, A., Jayaram, A., Varamballi, P., Mukhopadhyay, C., & Jagadesh, A. (2024). Surveillance of influenza A and B viruses from community and hospital wastewater treatment plants. Environmental Microbiology Reports, 16(4). https://doi.org/10.1111/1758-2229.13317

Vancouver

Panneerselvam S, Manayan Parambil A, Jayaram A, Varamballi P, Mukhopadhyay C, Jagadesh A. Surveillance of influenza A and B viruses from community and hospital wastewater treatment plants. Environmental Microbiology Reports. 2024;16(4). doi:10.1111/1758-2229.13317

BibTeX
@article{Panneerselvam2024,
  author = {Panneerselvam, Sneka and Manayan Parambil, Athira and Jayaram, Anup and Varamballi, Prasad and Mukhopadhyay, Chiranjay and Jagadesh, Anitha},
  title = {Surveillance of influenza A and B viruses from community and hospital wastewater treatment plants},
  journal = {Environmental Microbiology Reports},
  year = {2024},
  volume = {16},
  number = {4},
  doi = {10.1111/1758-2229.13317}
}
Kostenlos starten →