EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access

Diagnostic Performance of Magnetic Resonance Imaging in Chronic Thromboembolic Pulmonary Hypertension: A Systematic Review

Jeffrey Yong Yau Tai iD, Aphakorn Hasdarngkul, Ranon Earn Yueh Khoo, Brad Milner

Journal of Medical Imaging and Radiation Oncology · 2026-08 · 70 (5) · 421-428

DOI: 10.1111/1754-9485.70101 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Medical Imaging and Radiation Oncology, online erschienen am 12.04.2026. Verfasst von Jeffrey Yong Yau Tai und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, St Vincent's Hospital Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Hypertension, Pulmonary, Pulmonary Embolism, Magnetic Resonance Imaging. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Chronic thromboembolic pulmonary hypertension (CTEPH) requires accurate identification of thromboembolic and perfusion defects for diagnosis and operability assessment. Magnetic resonance imaging (MRI) provides radiation‐free evaluation of vascular morphology, perfusion distribution and cardiopulmonary function. However, its diagnostic performance in CTEPH has not been comprehensively synthesised.

Purpose

This review aimed to evaluate the diagnostic accuracy of MRI techniques for detecting chronic thromboembolic material and perfusion defects in CTEPH.

Methods

A systematic review was conducted according to PRISMA guidelines and was prospectively registered with PROSPERO (CRD420251134001). PubMed, Medline, Embase and Google Scholar were searched from January 2000 to October 2025 for studies assessing MRI‐based detection of CTEPH using accepted reference standards, including computed tomography pulmonary angiography (CTPA), digital subtraction angiography (DSA), ventilation–perfusion (V/Q) scintigraphy or multidisciplinary consensus. Eligible studies evaluated MRI perfusion, contrast‐enhanced MR angiography (ce‐MRA), non‐contrast MRA or advanced MRI techniques in adults with suspected or confirmed CTEPH. Data extraction was performed in duplicate, and the risk of bias was assessed using QUADAS‐2. Due to heterogeneity among the included studies, the Synthesis Without Meta‐analysis (SWiM) framework was used to guide data synthesis.

Results

Nine studies involving 563 participants met the inclusion criteria. Across eight MRI perfusion studies, the median sensitivity was 97% and the median specificity was 92.5%. Standard MRI perfusion demonstrated similar performance (median sensitivity 97%, specificity 92%). Three ce‐MRA studies yielded a median sensitivity of 87.7% and specificity of 98.1%. Non‐contrast MRA showed lower standalone diagnostic accuracy (sensitivity 45%, specificity 76%) but improved markedly when combined with ce‐MRA. Risk of bias was moderate to high across studies, driven primarily by non‐consecutive patient selection, variable reference standards and heterogeneity in MRI protocols.

Conclusion

MRI demonstrates encouraging diagnostic performance for detecting perfusion defects and chronic thromboembolic material in CTEPH, with MRI perfusion offering high sensitivity and ce‐MRA showing high specificity. Non‐contrast MRA adds value for proximal vessel assessment when used alongside ce‐MRA. However, methodological limitations and study heterogeneity constrain the certainty of existing evidence. Larger, standardised prospective studies are needed to define the precise role of MRI within contemporary CTEPH diagnostic pathways.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hypertension, PulmonaryPulmonary EmbolismMagnetic Resonance ImagingHumansChronic DiseaseSensitivity and Specificity

Autor:innen und Institutionen

  • Department of Medical Imaging, St Vincent's Hospital Sydney, New South Wales, Australia.
  • Concord Repatriation General Hospital, New South Wales, Australia.
  • Nepean Hospital, New South Wales, Australia.
  • University of New South Wales, New South Wales, Australia.

ORCID-Profile: Jeffrey Yong Yau Tai

Zitieren

APA

Tai, J. Y. Y., Hasdarngkul, A., Khoo, R. E. Y., & Milner, B. (2026). Diagnostic Performance of Magnetic Resonance Imaging in Chronic Thromboembolic Pulmonary Hypertension: A Systematic Review. Journal of Medical Imaging and Radiation Oncology, 70(5), 421-428. https://doi.org/10.1111/1754-9485.70101

Vancouver

Tai JYY, Hasdarngkul A, Khoo REY, Milner B. Diagnostic Performance of Magnetic Resonance Imaging in Chronic Thromboembolic Pulmonary Hypertension: A Systematic Review. Journal of Medical Imaging and Radiation Oncology. 2026;70(5):421-428. doi:10.1111/1754-9485.70101

BibTeX
@article{Tai2026,
  author = {Tai, Jeffrey Yong Yau and Hasdarngkul, Aphakorn and Khoo, Ranon Earn Yueh and Milner, Brad},
  title = {Diagnostic Performance of Magnetic Resonance Imaging in Chronic Thromboembolic Pulmonary Hypertension: A Systematic Review},
  journal = {Journal of Medical Imaging and Radiation Oncology},
  year = {2026},
  volume = {70},
  number = {5},
  pages = {421--428},
  doi = {10.1111/1754-9485.70101}
}
Kostenlos starten →