Exploration of Diffusion Tensor Imaging for Delineating Target Volume Boundary in Glioblastoma Radiotherapy
Journal of Medical Imaging and Radiation Oncology · 2025
DOI: 10.1111/1754-9485.13873 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Imaging and Radiation Oncology, 2025. Verfasst von Lei Tian und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiotherapy, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei, China. Hauptthemen laut MEDLINE: Glioblastoma, Diffusion Tensor Imaging, Brain Neoplasms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the S&T Program of Hebei.
Abstract (Originalsprache)
Purpose
The objective of this study is to investigate the variations in diffusion tensor imaging (DTI) parameters at different distances surrounding the operative cavity, with a specific focus on exploring the potential utility of DTI in accurately delineating radiotherapy clinical target volume for glioblastoma patients.
Methods
A retrospective study was conducted on 41 patients with glioblastoma, in which apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured at various distances beyond the surgical cavity. Recurrent patients were prospectively followed up according to the RANO criteria, aiming to investigate discrepancies between ADC and FA values in recurrent regions compared to normal control tissues prior to recurrence.
Results
The rADC and rFA ratio approach 1 at a distance of 3 cm beyond the cavity. At the edge of the operative cavity and 2 cm beyond, the subtotal resection (STR) group exhibited higher ADC and rADC values compared to the gross total resection (GTR) group ( p < 0.05). Similarly, FA and rFA values in the STR group were lower than those in the total resection group both at 1 cm beyond and 2 cm beyond ( p < 0.05). Conventional MRI did not reveal any abnormalities prior to marginal or distant recurrence; however, the ADC value within this region was higher than that of control normal tissues ( p = 0.023).
Conclusions
The margins of GBM tumour invasion are typically not isotropic and could be > 2 cm and sometimes up to 3 cm. We recommend appropriately larger expansion of the target volume for patients with subtotal tumour resection. The utilisation of DTI in delineating the boundary of GBM's radiotherapy clinical target volume represents a promising avenue that holds potential to enhance precision and accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiotherapy, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.
- Department of Radiotherapy, Affiliated Hospital of Hebei University, Baoding, Hebei, China.
ORCID-Profile: Xiaoying Xue
Förderung
- the S&T Program of Hebei
Zitieren
APA
Tian, L., Wang, W., Sun, W., Zhou, H., Xiao, Z., Han, X., Kang, X., & Xue, X. (2025). Exploration of Diffusion Tensor Imaging for Delineating Target Volume Boundary in Glioblastoma Radiotherapy. Journal of Medical Imaging and Radiation Oncology. https://doi.org/10.1111/1754-9485.13873
Vancouver
Tian L, Wang W, Sun W, Zhou H, Xiao Z, Han X, et al. Exploration of Diffusion Tensor Imaging for Delineating Target Volume Boundary in Glioblastoma Radiotherapy. Journal of Medical Imaging and Radiation Oncology. 2025. doi:10.1111/1754-9485.13873
BibTeX
@article{Tian2025,
author = {Tian, Lei and Wang, Wenyan and Sun, Wei and Zhou, Huandi and Xiao, Zhiqing and Han, Xuetao and Kang, Xing and Xue, Xiaoying},
title = {Exploration of Diffusion Tensor Imaging for Delineating Target Volume Boundary in Glioblastoma Radiotherapy},
journal = {Journal of Medical Imaging and Radiation Oncology},
year = {2025},
doi = {10.1111/1754-9485.13873}
}
EUVIMED