Feasibility study comparing synthesized mammography with digital breast tomosynthesis and digital mammography for simulated first round screening in a single BreastScreen NSW centre
Journal of Medical Imaging and Radiation Oncology · 2024-06 · 68 (4) · 401-411
DOI: 10.1111/1754-9485.13664 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Medical Imaging and Radiation Oncology, online erschienen am 02.05.2024. Verfasst von Vikrant Dhurandhar und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Royal North Shore Hospital, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Mammography, Breast Neoplasms, Feasibility Studies, Cost-Benefit Analysis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
Introduction
While digital breast tomosynthesis (DBT) has proven to enhance cancer detection and reduce recall rates (RR), its integration into BreastScreen Australia for screening has been limited, in part due to perceived cost implications. This study aims to assess the cost effectiveness of digital mammography (DM) compared with synthesized mammography and DBT (SM + DBT) in a first round screening context for short‐term outcomes.
Methods
Clients recalled for nonspecific density (NSD) as a single lesion by both readers at the Northern Sydney Central Coast BreastScreen service in 2019 were included. Prior images were excluded to simulate first‐round screening. Eleven radiologists read DM and synthesized mammography with DBT (SM + DBT) images 4 weeks apart. Recall rates (RR), reading time, and diagnostic parameters were measured, and costs for screen reading and assessment were calculated.
Result
Among 65 clients studied, 13 were diagnosed with cancer, with concordant cancer recalls. SM + DBT reduced recall rates (RR), increased reading time, maintained cancer detection sensitivity, and significantly improved other diagnostic parameters, particularly false positive rates. Benign biopsy recalls remained equivalent. While SM + DBT screen reading cost was significantly higher than DM (DM AU$890 ± 186 vs SM + DBT AU$1279 ± 265; P < 0.001), the assessment cost (DM AU$29,504 ± 9427 vs SM + DBT AU$18,021 ± 5606; P < 0.001), and combined screen reading and assessment costs were significantly lower (DM AU$30,394 ± 9508 vs SM + DBT AU$19,300 ± 5721; P = 0.001). SM + DBT screen reading and assessment of 65 patients resulted in noteworthy cost savings (AU$11,094), equivalent to assessing 12 additional clients.
Conclusion
In first round screening, DBT yields significant cost savings by effectively reducing unnecessary recalls to assessment while maintaining diagnostic efficacy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Royal North Shore Hospital, Sydney, New South Wales, Australia.
- Northern Sydney & Central Coast BreastScreen, Sydney, New South Wales, Australia.
ORCID-Profile: Vikrant Dhurandhar, Tzu-Yun Chung
Zitieren
APA
Dhurandhar, V., Bhola, N., Chan, M., Choi, S., Chung, T. Y., Giuffre, B., Hunter, N., Lee, K., McKessar, M., Reddy, R., Roberts, M., Shearman, C., Kay, M., Bruderlin, K., Winarta, N., & Noakes, J. (2024). Feasibility study comparing synthesized mammography with digital breast tomosynthesis and digital mammography for simulated first round screening in a single BreastScreen NSW centre. Journal of Medical Imaging and Radiation Oncology, 68(4), 401-411. https://doi.org/10.1111/1754-9485.13664
Vancouver
Dhurandhar V, Bhola N, Chan M, Choi S, Chung TY, Giuffre B, et al. Feasibility study comparing synthesized mammography with digital breast tomosynthesis and digital mammography for simulated first round screening in a single BreastScreen NSW centre. Journal of Medical Imaging and Radiation Oncology. 2024;68(4):401-411. doi:10.1111/1754-9485.13664
BibTeX
@article{Dhurandhar2024,
author = {Dhurandhar, Vikrant and Bhola, Nalini and Chan, Mico and Choi, Sarah and Chung, Tzu-Yun and Giuffre, Bruno and Hunter, Nigel and Lee, Katelyn and McKessar, Merran and Reddy, Ranjani and Roberts, Marian and Shearman, Christine and Kay, Meredith and Bruderlin, Ken and Winarta, Niko and Noakes, Jennifer},
title = {Feasibility study comparing synthesized mammography with digital breast tomosynthesis and digital mammography for simulated first round screening in a single BreastScreen NSW centre},
journal = {Journal of Medical Imaging and Radiation Oncology},
year = {2024},
volume = {68},
number = {4},
pages = {401--411},
doi = {10.1111/1754-9485.13664}
}
EUVIMED