EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

A Prospective Multicenter Assessment of the Accuracy and Safety of the Yuwell CT3 Real‐Time Continuous Glucose Monitoring System in Patients With Diabetes Over 14 Days

Lingli Zhou, Yufeng Li, Xingguang Zhang, Hongwei Ling, Yibing Lu, Linong Ji iD

Journal of Diabetes · 2026-07 · 18 (7)

DOI: 10.1111/1753-0407.70246 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Diabetes, online erschienen am 14.07.2026. Verfasst von Lingli Zhou und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrinology and Metabolism, Peking University People's Hospital, Beijing, China. Hauptthemen laut MEDLINE: Blood Glucose, Blood Glucose Self-Monitoring, Continuous Glucose Monitoring, Diabetes Mellitus. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Major Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Highlights This 14‐day multicenter study assessed CT3 CGM accuracy and safety in 71 adults with diabetes. Key results: overall MARD 9.1% (median 7.1%), 82.4%–98.2% met %15/15–%30/30 criteria, 99.7% values in CEG zones A/B. CT3 showed strong performance, suitable for reliable 14‐day wear.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood GlucoseBlood Glucose Self-MonitoringContinuous Glucose MonitoringDiabetes MellitusDiabetes Mellitus, Type 2AdultAgedFemaleHumansMiddle AgedProspective StudiesReproducibility of Results

Stichwörter der Autor:innen

CT3MARDaccuracycontinuous glucose monitoringerror grid analysis

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Department of Endocrinology and Metabolism, Peking University People's Hospital, Beijing, China.
  • Department of Endocrinology, Beijing Pinggu Hospital, Beijing, China.
  • Department of Endocrinology, Army General Hospital of Chinese PLA, Beijing, China.
  • Department of Endocrinology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China.
  • Department of Endocrinology, The Second Affiliated Hospital of Nanjing Medical University, Nanjing, China.

ORCID-Profile: Linong Ji

Förderung

  • National Science and Technology Major Project

Zitieren

APA

Zhou, L., Li, Y., Zhang, X., Ling, H., Lu, Y., & Ji, L. (2026). A Prospective Multicenter Assessment of the Accuracy and Safety of the Yuwell CT3 Real‐Time Continuous Glucose Monitoring System in Patients With Diabetes Over 14 Days. Journal of Diabetes, 18(7). https://doi.org/10.1111/1753-0407.70246

Vancouver

Zhou L, Li Y, Zhang X, Ling H, Lu Y, Ji L. A Prospective Multicenter Assessment of the Accuracy and Safety of the Yuwell CT3 Real‐Time Continuous Glucose Monitoring System in Patients With Diabetes Over 14 Days. Journal of Diabetes. 2026;18(7). doi:10.1111/1753-0407.70246

BibTeX
@article{Zhou2026,
  author = {Zhou, Lingli and Li, Yufeng and Zhang, Xingguang and Ling, Hongwei and Lu, Yibing and Ji, Linong},
  title = {A Prospective Multicenter Assessment of the Accuracy and Safety of the Yuwell CT3 Real‐Time Continuous Glucose Monitoring System in Patients With Diabetes Over 14 Days},
  journal = {Journal of Diabetes},
  year = {2026},
  volume = {18},
  number = {7},
  doi = {10.1111/1753-0407.70246}
}
Kostenlos starten →