EUVIMEDEUVIMED entdecken
Crossref

A Prediction Framework for Quantification of Milk Adulterants Using a NIR‐Coupled Boosting Algorithm

Naveen G Jesubalan, Hemlata Chhabra, Anurag S Rathore iD

Journal of Food Science · 2026-03 · 91 (3)

DOI: 10.1111/1750-3841.70966 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Food Science, online erschienen am 09.03.2026. Verfasst von Naveen G Jesubalan und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Interdisciplinary Research, Indian Institute of Technology, Delhi, India. Hauptthemen laut MEDLINE: Milk, Food Contamination. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 81 Literaturangaben. Gefördert von: Department of Biotechnology, Ministry of Science and Technology, Tata Consultancy Services, Department of Biotechnology, Ministry of Science and Technology, India.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Milk adulteration remains a significant global food safety concern, given the widespread consumption of milk by billions worldwide. This study presents a soft sensor for quantifying concentrations of common milk adulterants, including ammonia, urea, sugar, and hydrogen peroxide. The approach integrates near‐infrared (NIR) spectroscopy with a chemometric framework for real‐time measurement. Orthogonal partial least squares (OPLS) was coupled with the XGBoost algorithm, leveraging its ensemble boosting mechanism and resistance to overfitting. K‐means random clustering was used to organize experimental trials during model development. The soft sensor demonstrated high predictive performance, with root mean squared error (RMSE), normalized root mean squared error (NRMSE), and cross validation – coefficient of correlation (CV‐R 2 ) values of 0.01, 0.02, and 0.97 for urea; 0.01, 0.02, and 0.96 for ammonium sulfate; 0.07, 0.13, and 0.95 for sugar; and 0.01, 0.03, and 0.94 for H 2 O 2 . For all the adulterants, R 2 and the other variants of R 2 (adjusted and multiple) values were higher than 0.95, thereby demonstrating the exceptional performance of the developed soft sensor. The soft sensor provided accurate real‐time values with an average error rate of less than 10%. Overall, the results demonstrate that the developed NIR‐chemometric soft sensor provides a rapid, non‐destructive, and reliable method for detecting and quantifying multiple milk adulterants in real time, offering significant potential for food safety monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MilkFood ContaminationAnimalsSpectroscopy, Near-InfraredBoosting Machine Learning AlgorithmsHydrogen PeroxidePrediction AlgorithmsUreaLeast-Squares AnalysisAmmoniaAlgorithmsCarbohydrates

Stichwörter der Autor:innen

NIR spectroscopychemometricsensemble learningmilk adulterantssoft sensors

Substanzen

Hydrogen PeroxideUreaAmmoniaCarbohydrates

Autor:innen und Institutionen

  • School of Interdisciplinary Research, Indian Institute of Technology, Delhi, India.
  • Department of Chemical Engineering, Indian Institute of Technology, Delhi, India.

ORCID-Profile: Anurag S Rathore

Förderung

  • Department of Biotechnology, Ministry of Science and Technology
  • Tata Consultancy Services
  • Department of Biotechnology, Ministry of Science and Technology, India

Zitieren

APA

Jesubalan, N. G., Chhabra, H., & Rathore, A. S. (2026). A Prediction Framework for Quantification of Milk Adulterants Using a NIR‐Coupled Boosting Algorithm. Journal of Food Science, 91(3). https://doi.org/10.1111/1750-3841.70966

Vancouver

Jesubalan NG, Chhabra H, Rathore AS. A Prediction Framework for Quantification of Milk Adulterants Using a NIR‐Coupled Boosting Algorithm. Journal of Food Science. 2026;91(3). doi:10.1111/1750-3841.70966

BibTeX
@article{Jesubalan2026,
  author = {Jesubalan, Naveen G and Chhabra, Hemlata and Rathore, Anurag S},
  title = {A Prediction Framework for Quantification of Milk Adulterants Using a NIR‐Coupled Boosting Algorithm},
  journal = {Journal of Food Science},
  year = {2026},
  volume = {91},
  number = {3},
  doi = {10.1111/1750-3841.70966}
}
Kostenlos starten →