Reliability and benefit of estimated continuous cardiac output measurement using shunt‐side SpO 2 monitor in hemodialysis
Therapeutic Apheresis and Dialysis · 2025
DOI: 10.1111/1744-9987.14193 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Therapeutic Apheresis and Dialysis, 2025. Verfasst von Koji Nakai und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Life and Health Sciences, Department of Clinical Engineering, Chubu University, Kasugai, Japan. Hauptthemen laut MEDLINE: Renal Dialysis, Cardiac Output, Arteriovenous Shunt, Surgical. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
Estimated continuous cardiac output (esCCO) is a novel technology that enables non‐invasive and continuous monitoring of cardiac output. We compared the concordance in accuracies among esCCO measurements in the shunt limb and non‐shunt limb.
Methods
In this single‐center prospective observational study, we include Japanese patients who underwent dialysis at our center between April 27, 2021, and February 28, 2023. Clinical accuracy of esCCO was evaluated in the shunted and non‐shunted bilateral digits. Agreement between the measurements was analyzed using Lin's congruent correlation and Bland–Altman analysis.
Results
For 43 individuals, Lin's concordance correlation coefficient was 0.9887 (95% confidence interval of 0.9886–0.9887) indicating good agreement. The values of esCCO measured in the shunt and non‐shunt limbs were compatible. The percentage errors for the 43 patients with arterio‐venous fistula (AVF) or arterio‐venous graft (AVG), 32 with AVF, and 11 with AVG were 9.3%, 9.3%, and 8.9%, respectively. Conclusion esCCO could be used in shunt as well as non‐shunt limbs during dialysis, allowing continuous and non‐invasive hemodynamic monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Life and Health Sciences, Department of Clinical Engineering, Chubu University, Kasugai, Japan.
- Department of Nephrology, Nagoya Ekisaikai Hospital, Nagoya, Japan.
- Department of Clinical Engineering, Nagoya Ekisaikai Hospital, Nagoya, Japan.
- Department of Anesthesiology, Aichi Cancer Center, Nagoya, Japan.
ORCID-Profile: Koji Nakai
Zitieren
APA
Nakai, K., Hirate, Y., Nakajima, T., Doi, A., Hiramatsu, T., Higaki, T., & Nakai, A. (2025). Reliability and benefit of estimated continuous cardiac output measurement using shunt‐side SpO 2 monitor in hemodialysis. Therapeutic Apheresis and Dialysis. https://doi.org/10.1111/1744-9987.14193
Vancouver
Nakai K, Hirate Y, Nakajima T, Doi A, Hiramatsu T, Higaki T, et al. Reliability and benefit of estimated continuous cardiac output measurement using shunt‐side SpO 2 monitor in hemodialysis. Therapeutic Apheresis and Dialysis. 2025. doi:10.1111/1744-9987.14193
BibTeX
@article{Nakai2025,
author = {Nakai, Koji and Hirate, Yuichi and Nakajima, Takashi and Doi, Atsushi and Hiramatsu, Takeyuki and Higaki, Toshie and Nakai, Aiko},
title = {Reliability and benefit of estimated continuous cardiac output measurement using shunt‐side SpO 2 monitor in hemodialysis},
journal = {Therapeutic Apheresis and Dialysis},
year = {2025},
doi = {10.1111/1744-9987.14193}
}
EUVIMED