EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudie

Fibrinogen levels in severe trauma: A preliminary comparison of Clauss Fibrinogen , ROTEM Sigma , ROTEM Delta and TEG 6s assays from the FEISTY pilot randomised clinical trial

Travis Auty iD, James McCullough, Ian Hughes iD, Jonathon P Fanning iD, Sarah Czuchwicki iD, James Winearls iD

Emergency Medicine Australasia · 2024

DOI: 10.1111/1742-6723.14356 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Emergency Medicine Australasia, 2024. Verfasst von Travis Auty und 5 weiteren Autor:innen. Beteiligte Einrichtung: Intensive Care Unit, Rockhampton Hospital, Rockhampton, Queensland, Australia. Hauptthemen laut MEDLINE: Fibrinogen, Thrombelastography, Wounds and Injuries. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To describe the relationships between different methods of measuring functional fibrinogen levels in severely injured, bleeding trauma patients across multiple timepoints during hospitalisation.

Methods

In 100 adult trauma patients enrolled in the FEISTY pilot randomised clinical trial at four tertiary trauma centres in Australia, blood samples were collected prospectively. Consistency of agreement was calculated, comparing functional fibrinogen levels measured by four methods – ROTEM® Delta and Sigma FIBTEM A5, TEG® 6s CFF MA, and gold‐standard Clauss Fibrinogen.

Results

Comparing the ROTEM® Delta and new‐generation ROTEM® Sigma machine, consistency of agreement for FIBTEM A5, measured by calculating intraclass correlation coefficients (ICCs), was ≥0.73 across all analysed timepoints, with mean differences (Sigma minus Delta) of 0.10–3.57 mm. Corresponding values comparing the ROTEM® Sigma FIBTEM A5 and TEG® 6s CFF MA were ICC = 0.55–0.82 and ICC = 4.69–7.97 (CFF MA minus A5). Comparing ROTEM® Sigma FIBTEM A5 and Clauss Fibrinogen Analysis (CFA), among statistically significant simple linear regression models, R 2 was 0.25–0.67, and comparing TEG® 6s CFF MA and CFA (CFA) 0.65–0.82, although not all differences were significant with the latter comparison. Relationships across all timepoints combined were Clauss Fibrinogen (CF) (g/L) = 0.21𝑥 + 0.004 (where 𝑥 = ROTEM® Sigma FIBTEM A5 in mm) and (g/L) = 0.16𝑥 − 0.06 (where 𝑥 = TEG® 6s CFF MA in mm).

Conclusions

The present study revealed acceptable agreement between four different assays measuring functional fibrinogen, with current‐ and previous‐generation ROTEM® machines (Sigma, Delta) performing similarly measuring functional fibrinogen via FIBTEM assay. This suggests that haemostatic resuscitation algorithms designed for the ROTEM® Delta can be applied to the ROTEM® Sigma to guide fibrinogen replacement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FibrinogenThrombelastographyWounds and InjuriesHumansMaleFemalePilot ProjectsAdultMiddle AgedAustraliaProspective StudiesBlood Coagulation TestsHemorrhage

Stichwörter der Autor:innen

coagulopathyfibrinogenhaemorrhagerotational thromboelastometrytrauma

Substanzen

Fibrinogen

Autor:innen und Institutionen

  • Intensive Care Unit, Rockhampton Hospital, Rockhampton, Queensland, Australia.
  • Intensive Care Unit, Gold Coast University Hospital, Gold Coast, Queensland, Australia.
  • Griffith University, Gold Coast, Queensland, Australia.
  • Office for Research Governance and Development, Gold Coast University Hospital, Brisbane, Queensland, Australia.
  • University of Queensland, Brisbane, Queensland, Australia.
  • Intensive Care Unit, St Andrew's War Memorial Hospital, UnitingCare Health, Brisbane, Queensland, Australia.

ORCID-Profile: Travis Auty, Ian Hughes, Jonathon P Fanning, Sarah Czuchwicki, James Winearls

Zitieren

APA

Auty, T., McCullough, J., Hughes, I., Fanning, J. P., Czuchwicki, S., & Winearls, J. (2024). Fibrinogen levels in severe trauma: A preliminary comparison of Clauss Fibrinogen , ROTEM Sigma , ROTEM Delta and TEG 6s assays from the FEISTY pilot randomised clinical trial. Emergency Medicine Australasia. https://doi.org/10.1111/1742-6723.14356

Vancouver

Auty T, McCullough J, Hughes I, Fanning JP, Czuchwicki S, Winearls J. Fibrinogen levels in severe trauma: A preliminary comparison of Clauss Fibrinogen , ROTEM Sigma , ROTEM Delta and TEG 6s assays from the FEISTY pilot randomised clinical trial. Emergency Medicine Australasia. 2024. doi:10.1111/1742-6723.14356

BibTeX
@article{Auty2024,
  author = {Auty, Travis and McCullough, James and Hughes, Ian and Fanning, Jonathon P and Czuchwicki, Sarah and Winearls, James},
  title = {Fibrinogen levels in severe trauma: A preliminary comparison of Clauss Fibrinogen , ROTEM Sigma , ROTEM Delta and TEG 6s assays from the FEISTY pilot randomised clinical trial},
  journal = {Emergency Medicine Australasia},
  year = {2024},
  doi = {10.1111/1742-6723.14356}
}
Kostenlos starten →