EUVIMEDEUVIMED entdecken
Evaluationsstudie

Evaluation of the ForenSeq ™ MainstAY workflow for forensic DNA samples

Lucio L Avellaneda, Ryan M Gutierrez, Damani T Johnson, Tim Kalafut, Rachel M Houston iD

Journal of Forensic Sciences · 2026

DOI: 10.1111/1556-4029.70263 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Forensic Sciences, 2026. Verfasst von Lucio L Avellaneda und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Forensic Science, College of Criminal Justice, Sam Houston State University, Huntsville, Texas, USA. Hauptthemen laut MEDLINE: DNA Fingerprinting, High-Throughput Nucleotide Sequencing, Workflow, Sequence Analysis, DNA. Die Arbeit nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated the performance and limitations of the ForenSeq™ MainstAY chemistry on the MiSeq FGx® Sequencing System, which is approved for National DNA Index System (NDIS) use. This study included baseline performance, sensitivity and reproducibility studies, challenging casework samples, assessments of library plexities, comparisons with capillary electrophoresis (CE), standard versus enhanced PCR1 buffers, manual versus automated library preparation, and different flow cell types. To assess reproducibility across users, 33 samples were prepared by both an experienced and a novice user. Overall, the ForenSeq™ MainstAY Kit demonstrated high reliability with pristine samples and consistent performance across users, with minimal locus dropout until 62 pg. The kit outperformed CE for low‐input and degraded samples, but limitations were observed at higher plexities. Increased sample numbers on a single flow cell disproportionately reduced read counts and locus recovery in degraded casework samples, while pristine samples were less affected. Strategic adjustments, such as batching degraded samples together or lowering plexity, may help mitigate these effects. Casework samples, including blood, touched items, bone, hair, and tissue, were tested with both standard and enhanced PCR1 buffers. In a 64‐sample run (32 per buffer type), increased multiplexing reduced locus recovery in standard buffer samples, while the enhanced buffer improved recovery in 16 samples. Automated library preparation on the Opentrons OT‐2 produced comparable or improved recovery relative to manual preparation, with no evidence of cross‐contamination. These findings provide practical guidance for forensic laboratories adopting the MainstAY Kit, particularly in optimizing workflows for challenging samples and high‐throughput sequencing environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DNA FingerprintingHigh-Throughput Nucleotide SequencingWorkflowSequence Analysis, DNADNAHumansReproducibility of ResultsElectrophoresis, CapillaryMicrosatellite RepeatsBone and BonesHairPolymerase Chain ReactionGene LibraryTouchBuffersDNA Degradation, Necrotic

Stichwörter der Autor:innen

ForenSeq™ MainstAY KitMiSeq FGx® Sequencing Systemautomationdegraded DNAnext‐generation sequencingplexityshort tandem repeats

Substanzen

DNABuffers

Autor:innen und Institutionen

  • Department of Forensic Science, College of Criminal Justice, Sam Houston State University, Huntsville, Texas, USA.

ORCID-Profile: Rachel M Houston

Zitieren

APA

Avellaneda, L. L., Gutierrez, R. M., Johnson, D. T., Kalafut, T., & Houston, R. M. (2026). Evaluation of the ForenSeq ™ MainstAY workflow for forensic DNA samples. Journal of Forensic Sciences. https://doi.org/10.1111/1556-4029.70263

Vancouver

Avellaneda LL, Gutierrez RM, Johnson DT, Kalafut T, Houston RM. Evaluation of the ForenSeq ™ MainstAY workflow for forensic DNA samples. Journal of Forensic Sciences. 2026. doi:10.1111/1556-4029.70263

BibTeX
@article{Avellaneda2026,
  author = {Avellaneda, Lucio L and Gutierrez, Ryan M and Johnson, Damani T and Kalafut, Tim and Houston, Rachel M},
  title = {Evaluation of the ForenSeq ™ MainstAY workflow for forensic DNA samples},
  journal = {Journal of Forensic Sciences},
  year = {2026},
  doi = {10.1111/1556-4029.70263}
}
Kostenlos starten →