A comparative analysis of accuracy and sensitivity in semen testing: ABAcard p30™ , RSID Semen™ , and Seratec PSA™
Journal of Forensic Sciences · 2026
DOI: 10.1111/1556-4029.70194 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Forensic Sciences, 2026. Verfasst von Heather Rogers und 1 weiteren Autor:innen. Beteiligte Einrichtung: University of Central Oklahoma, Edmond, Oklahoma, USA. Hauptthemen laut MEDLINE: Semen, Seminal Vesicle Secretory Proteins, Reagent Kits, Diagnostic, Chromatography, Affinity. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 13 Literaturangaben. Gefördert von: University of Central Oklahoma.
Abstract (Originalsprache)
Confirmatory semen tests are used to determine the possible presence of semen in an evidence sample. Current test kits target proteins like PSA and semenogelin, but these markers can yield false positive results when identifying potential semen evidence. This study evaluated the sensitivity and specificity of three rapid immunochromatographic semen detection kits: RSID™ Semen, Seratec™ PSA, and ABAcard™ p30. These kits are marketed as confirmatory tests for semen. Test samples included serial semen dilutions, bodily fluids, and materials previously shown to cause false positives. All tests were performed according to manufacturers' protocols. Combined test results indicated a 9.4% false positive rate. False positives occurred across all kits with absorbent hygiene products (e.g., tampons, menstrual pads, and diapers). RSID™ Semen failed to detect semen in a 1:10,000 dilution and when mixed with dirt, indicating a 3% false negative rate and a false positive rate of 9%. ABAcard™ p30 produced false positives with female urine. While Seratec™ PSA demonstrated the highest sensitivity with only a 1% false negative rate, its false positive rate (12%) was the highest observed. ABAcard™ p30 exhibited superior performance with the lowest false positive rate (6%) and a false negative rate of 2%. While most forensic labs have moved away from using these kits as confirmatory tests, it is vital to emphasize why reporting their results as definitive semen evidence is problematic. These tests cannot confirm semen presence and should not be used alone as confirmatory evidence in forensic reports.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- University of Central Oklahoma, Edmond, Oklahoma, USA.
Förderung
- University of Central Oklahoma
Zitieren
APA
Rogers, H., & Williams, R. C. (2026). A comparative analysis of accuracy and sensitivity in semen testing: ABAcard p30™ , RSID Semen™ , and Seratec PSA™. Journal of Forensic Sciences. https://doi.org/10.1111/1556-4029.70194
Vancouver
Rogers H, Williams RC. A comparative analysis of accuracy and sensitivity in semen testing: ABAcard p30™ , RSID Semen™ , and Seratec PSA™. Journal of Forensic Sciences. 2026. doi:10.1111/1556-4029.70194
BibTeX
@article{Rogers2026,
author = {Rogers, Heather and Williams, Rhonda C},
title = {A comparative analysis of accuracy and sensitivity in semen testing: ABAcard p30™ , RSID Semen™ , and Seratec PSA™},
journal = {Journal of Forensic Sciences},
year = {2026},
doi = {10.1111/1556-4029.70194}
}
EUVIMED