EUVIMEDEUVIMED entdecken
Validierungsstudie

Optimization and validation of a method for rapid quantitation of fentanyl in seized‐drug samples using direct analysis in real time mass spectrometry (DART‐MS)

Sandra E Rodriguez-Cruz

Journal of Forensic Sciences · 2025

DOI: 10.1111/1556-4029.70156 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Forensic Sciences, 2025. Verfasst von Sandra E Rodriguez-Cruz. Beteiligte Einrichtung: Special Testing and Research Laboratory, Drug Enforcement Administration, Dulles, Virginia, USA. Hauptthemen laut MEDLINE: Fentanyl, Mass Spectrometry, Illicit Drugs, Narcotics. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rise of illicitly manufactured fentanyl and fentanyl‐related substances has overwhelmed seized‐drug laboratories and resulted in an explosive surge of analysis requests, increasing backlogs and turn‐around times. Direct analysis in real time (DART) ionization in combination with mass spectrometry has proven valuable as an identification tool for forensic laboratories by providing fast and reliable results. However, its application for quantitative analyses has been limited. In this work, the standardized DART‐mass spectrometry (MS) qualitative method used throughout Drug Enforcement Administration laboratories was optimized and validated for rapid quantitation of fentanyl‐containing samples. Sample solutions were prepared in methanol and ionized using a 3‐s pulse of metastable helium atoms, while protonated molecular ions for fentanyl and fentanyl‐d5 were monitored over a 12‐s MS acquisition window using selected‐ion monitoring. Measured peak area ratios resulted in great linear behavior ( r > 0.999) over a fentanyl concentration range of 2–250 μg/mL and a calculated LOQ of 3.8 μg/mL. Validation of the method demonstrated excellent within‐batch and between‐day precision (relative standard deviations

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FentanylMass SpectrometryIllicit DrugsNarcoticsHumansForensic ToxicologyReproducibility of Results

Stichwörter der Autor:innen

DART‐MSfentanylopioid epidemicquantitative analysisseized drugsvalidation

Substanzen

FentanylIllicit DrugsNarcotics

Autor:innen und Institutionen

  • Special Testing and Research Laboratory, Drug Enforcement Administration, Dulles, Virginia, USA.

Zitieren

APA

Rodriguez-Cruz, S. E. (2025). Optimization and validation of a method for rapid quantitation of fentanyl in seized‐drug samples using direct analysis in real time mass spectrometry (DART‐MS). Journal of Forensic Sciences. https://doi.org/10.1111/1556-4029.70156

Vancouver

Rodriguez-Cruz SE. Optimization and validation of a method for rapid quantitation of fentanyl in seized‐drug samples using direct analysis in real time mass spectrometry (DART‐MS). Journal of Forensic Sciences. 2025. doi:10.1111/1556-4029.70156

BibTeX
@article{RodriguezCruz2025,
  author = {Rodriguez-Cruz, Sandra E},
  title = {Optimization and validation of a method for rapid quantitation of fentanyl in seized‐drug samples using direct analysis in real time mass spectrometry (DART‐MS)},
  journal = {Journal of Forensic Sciences},
  year = {2025},
  doi = {10.1111/1556-4029.70156}
}
Kostenlos starten →