Optimization and validation of a method for rapid quantitation of fentanyl in seized‐drug samples using direct analysis in real time mass spectrometry (DART‐MS)
Journal of Forensic Sciences · 2025
DOI: 10.1111/1556-4029.70156 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Forensic Sciences, 2025. Verfasst von Sandra E Rodriguez-Cruz. Beteiligte Einrichtung: Special Testing and Research Laboratory, Drug Enforcement Administration, Dulles, Virginia, USA. Hauptthemen laut MEDLINE: Fentanyl, Mass Spectrometry, Illicit Drugs, Narcotics. Die Arbeit nennt 22 Literaturangaben.
Abstract (Originalsprache)
The rise of illicitly manufactured fentanyl and fentanyl‐related substances has overwhelmed seized‐drug laboratories and resulted in an explosive surge of analysis requests, increasing backlogs and turn‐around times. Direct analysis in real time (DART) ionization in combination with mass spectrometry has proven valuable as an identification tool for forensic laboratories by providing fast and reliable results. However, its application for quantitative analyses has been limited. In this work, the standardized DART‐mass spectrometry (MS) qualitative method used throughout Drug Enforcement Administration laboratories was optimized and validated for rapid quantitation of fentanyl‐containing samples. Sample solutions were prepared in methanol and ionized using a 3‐s pulse of metastable helium atoms, while protonated molecular ions for fentanyl and fentanyl‐d5 were monitored over a 12‐s MS acquisition window using selected‐ion monitoring. Measured peak area ratios resulted in great linear behavior ( r > 0.999) over a fentanyl concentration range of 2–250 μg/mL and a calculated LOQ of 3.8 μg/mL. Validation of the method demonstrated excellent within‐batch and between‐day precision (relative standard deviations
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Special Testing and Research Laboratory, Drug Enforcement Administration, Dulles, Virginia, USA.
Zitieren
APA
Rodriguez-Cruz, S. E. (2025). Optimization and validation of a method for rapid quantitation of fentanyl in seized‐drug samples using direct analysis in real time mass spectrometry (DART‐MS). Journal of Forensic Sciences. https://doi.org/10.1111/1556-4029.70156
Vancouver
Rodriguez-Cruz SE. Optimization and validation of a method for rapid quantitation of fentanyl in seized‐drug samples using direct analysis in real time mass spectrometry (DART‐MS). Journal of Forensic Sciences. 2025. doi:10.1111/1556-4029.70156
BibTeX
@article{RodriguezCruz2025,
author = {Rodriguez-Cruz, Sandra E},
title = {Optimization and validation of a method for rapid quantitation of fentanyl in seized‐drug samples using direct analysis in real time mass spectrometry (DART‐MS)},
journal = {Journal of Forensic Sciences},
year = {2025},
doi = {10.1111/1556-4029.70156}
}
EUVIMED