The impacts of thermocouple insulation failure on the accuracy of temperature measurement data in forensic fire‐death scenarios—Part II : Low electrical resistance and contamination
Journal of Forensic Sciences · 2024
DOI: 10.1111/1556-4029.15577 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Forensic Sciences, 2024. Verfasst von David Silveira und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, California State University, Chico, California, USA. Hauptthemen laut MEDLINE: Fires. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
Part II of this two‐part article investigates the impact of thermocouple insulation failure on temperature measurement data in forensic fire‐death scenarios. Two different models of glass fiber‐insulated thermocouple wires (GG‐K‐24‐SLE and HH‐K‐24 from Omega Engineering) were passed through a ceramic kiln at temperatures up to 1093°C to measure an ice bath at a constant 0°C. In a separate experiment, the same two models of thermocouple wire plus a BLMI‐XL‐K‐18U‐120 mineral‐insulated metal‐sheathed thermocouple probe were passed through a wood pallet fire to measure an ice bath. In the ceramic kiln, the effect on measurement errors was determined for short vs. long exposure lengths and clean insulation vs. insulation contaminated with pork fat. Glass fiber‐insulated thermocouple wires showed severe failure in both experiments, with errors ranging from −270°C to almost 2200°C. The metal‐sheathed probe showed no evidence of insulation failure and continued to accurately measure the ice bath temperature within expected margins of error around 0°C. This study highlights how exposure of inadequate thermocouples to fire‐level temperatures produces severe errors in temperature data. Consequently, it will not be possible to use this data to draw any accurate conclusions about the effects of fire exposure to human donors or animal proxies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical and Computer Engineering, California State University, Chico, California, USA.
- Department of Anthropology, California State University, Chico, California, USA.
ORCID-Profile: David Silveira, Ashley Kendell
Zitieren
APA
Silveira, D., Kendell, A., & Shook, B. (2024). The impacts of thermocouple insulation failure on the accuracy of temperature measurement data in forensic fire‐death scenarios—Part II : Low electrical resistance and contamination. Journal of Forensic Sciences. https://doi.org/10.1111/1556-4029.15577
Vancouver
Silveira D, Kendell A, Shook B. The impacts of thermocouple insulation failure on the accuracy of temperature measurement data in forensic fire‐death scenarios—Part II : Low electrical resistance and contamination. Journal of Forensic Sciences. 2024. doi:10.1111/1556-4029.15577
BibTeX
@article{Silveira2024,
author = {Silveira, David and Kendell, Ashley and Shook, Beth},
title = {The impacts of thermocouple insulation failure on the accuracy of temperature measurement data in forensic fire‐death scenarios—Part II : Low electrical resistance and contamination},
journal = {Journal of Forensic Sciences},
year = {2024},
doi = {10.1111/1556-4029.15577}
}
EUVIMED