Strategies to detect trace methamphetamine contamination on hard surfaces: Assessing realistic performance of commercially available presumptive tests and a laboratory‐based LC–MS / MS method

William Naviaux, Curtis Hedman, Heather Barkholtz

Journal of Forensic Sciences · 2024

DOI: 10.1111/1556-4029.15491 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Forensic Sciences, 2024. Verfasst von William Naviaux und 2 weiteren Autor:innen. Beteiligte Einrichtung: Forensic Toxicology Section, Environmental Health Division, Wisconsin State Laboratory of Hygiene, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Methamphetamine, Limit of Detection, Forensic Toxicology. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Wisconsin Department of Health Services.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recreational methamphetamine production and heavy use can result in dwelling contamination that is difficult to detect. First responders and public health officials may use commercially available trace methamphetamine detection (presumptive) test kits to understand apparent and hidden dangers in impacted dwellings. Here, we assessed the limit of detection (LOD) of several commercially available presumptive test kits using simulated contaminated hard surfaces. Pyrex petri dishes were spiked with aliquots of methanolic methamphetamine solutions to reach desired simulated contamination levels. Commercially available presumptive tests were conducted according to manufacturer instructions and using included sample preparation materials, when available. Additionally, a laboratory‐based liquid chromatography‐triple quadrupole mass spectrometer (LC–MS/MS) trace methamphetamine quantification method was developed and validated using the EZSTATSG2 tool. For the LC–MS/MS method, samples were collected using 2‐ply alcohol prep pads and methamphetamine was extracted using a 1:1 (v:v) methanol: water solution. Most presumptive tests considered were able to detect trace levels of methamphetamine extracted from hard surfaces, with LOD ranging from 0.10–15.00 μg/sample. Comparatively, the laboratory‐based LC–MS/MS LOD was 0.05 μg/sample and limit of quantitation was 0.10 μg/sample. The LC–MS/MS method may be useful when the presence of dust or other contaminants interferes with presumptive test interpretation or reliability. Costs of presumptive tests varied from several dollars to tens of dollars, which is included alongside LOD results to aid stakeholders in identifying which test(s) are the best fit for purpose. Therefore, first responders, public health officials, and other stakeholders have several options for assessing trace methamphetamine contamination.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MethamphetamineLimit of DetectionForensic ToxicologyChromatography, LiquidHumansCentral Nervous System StimulantsTandem Mass SpectrometrySurface PropertiesMass SpectrometryLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

colorimetricdecontaminationimmunoassayliquid chromatography–tandem mass spectrometry (LC–MS/MS)methamphetaminesurface contamination

Substanzen

MethamphetamineCentral Nervous System Stimulants

Autor:innen und Institutionen

  • Forensic Toxicology Section, Environmental Health Division, Wisconsin State Laboratory of Hygiene, Madison, Wisconsin, USA.
  • Pharmacology and Toxicology Program, School of Pharmacy, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Bureau of Environmental and Occupational Health, Division of Public Health, Wisconsin Department of Health Services, Madison, Wisconsin, USA.
  • Pharmaceutical Sciences Division, School of Pharmacy, University of Wisconsin-Madison, Madison, Wisconsin, USA.

Förderung

  • Wisconsin Department of Health Services

Zitieren

APA

Naviaux, W., Hedman, C., & Barkholtz, H. (2024). Strategies to detect trace methamphetamine contamination on hard surfaces: Assessing realistic performance of commercially available presumptive tests and a laboratory‐based LC–MS / MS method. Journal of Forensic Sciences. https://doi.org/10.1111/1556-4029.15491

Vancouver

Naviaux W, Hedman C, Barkholtz H. Strategies to detect trace methamphetamine contamination on hard surfaces: Assessing realistic performance of commercially available presumptive tests and a laboratory‐based LC–MS / MS method. Journal of Forensic Sciences. 2024. doi:10.1111/1556-4029.15491

BibTeX
@article{Naviaux2024,
  author = {Naviaux, William and Hedman, Curtis and Barkholtz, Heather},
  title = {Strategies to detect trace methamphetamine contamination on hard surfaces: Assessing realistic performance of commercially available presumptive tests and a laboratory‐based LC–MS / MS method},
  journal = {Journal of Forensic Sciences},
  year = {2024},
  doi = {10.1111/1556-4029.15491}
}
Kostenlos starten →