EUVIMEDEUVIMED entdecken
Crossref

A diagnosis of the primary difference between EuroForMix and STRmix ™

John Buckleton, Mateusz Susik, James M Curran, Kevin Cheng iD, Duncan Taylor, Jo-Anne Bright, Hannah Kelly, Richard Wivell

Journal of Forensic Sciences · 2024-01 · 69 (1) · 40-51

DOI: 10.1111/1556-4029.15387 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Forensic Sciences, online erschienen am 27.09.2023. Verfasst von John Buckleton und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Environmental Science and Research Limited, Auckland, New Zealand. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: US National Institute of Justice.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

There is interest in comparing the output, principally the likelihood ratio, from the two probabilistic genotyping software EuroForMix (EFM) and STRmix™. Many of these comparison studies are descriptive and make little or no effort to diagnose the cause of difference. There are fundamental differences between EFM and STRmix™ that are causative of the largest set of likelihood ratio differences. This set of differences is for false donors where there are many instances of LR s just above or below 1 for EFM that give much lower LR s in STRmix™. This is caused by the separate estimation of parameters such as allele height variance and mixture proportion using MLE under H p and H a for EFM. This can result in very different estimations of these parameters under H p and H a . It results in a departure from calibration for EFM in the region of LR s just above and below 1.

Schlagwörter

Stichwörter der Autor:innen

EuroForMixSTRmix™forensic DNAprobabilistic genotypingreliabilityvalidation

Autor:innen und Institutionen

  • Institute of Environmental Science and Research Limited, Auckland, New Zealand.
  • Department of Statistics, University of Auckland, Auckland, New Zealand.
  • Biotype GmbH, Dresden, Germany.
  • Faculty of Computer Science, Technische Universit¨ at Dresden, Dresden, Germany.
  • Forensic Science SA, Adelaide, South Australia, Australia.
  • School of Biological Sciences, Flinders University, Adelaide, South Australia, Australia.

ORCID-Profile: Kevin Cheng

Förderung

  • US National Institute of Justice

Zitieren

APA

Buckleton, J., Susik, M., Curran, J. M., Cheng, K., Taylor, D., Bright, J. A., Kelly, H., & Wivell, R. (2024). A diagnosis of the primary difference between EuroForMix and STRmix ™. Journal of Forensic Sciences, 69(1), 40-51. https://doi.org/10.1111/1556-4029.15387

Vancouver

Buckleton J, Susik M, Curran JM, Cheng K, Taylor D, Bright JA, et al. A diagnosis of the primary difference between EuroForMix and STRmix ™. Journal of Forensic Sciences. 2024;69(1):40-51. doi:10.1111/1556-4029.15387

BibTeX
@article{Buckleton2024,
  author = {Buckleton, John and Susik, Mateusz and Curran, James M and Cheng, Kevin and Taylor, Duncan and Bright, Jo-Anne and Kelly, Hannah and Wivell, Richard},
  title = {A diagnosis of the primary difference between EuroForMix and STRmix ™},
  journal = {Journal of Forensic Sciences},
  year = {2024},
  volume = {69},
  number = {1},
  pages = {40--51},
  doi = {10.1111/1556-4029.15387}
}
Kostenlos starten →