Synergistic Inactivation of Airborne Viruses by Low‐Concentration Ozone With High Humidity and Temperature
Microbiology and Immunology · 2025
DOI: 10.1111/1348-0421.13204 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microbiology and Immunology, 2025. Verfasst von Hidekazu Nishimura und 9 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Research Division, Virus Research Center, Sendai Medical Center, National Hospital Organization, Sendai, Japan. Hauptthemen laut MEDLINE: Ozone, Humidity, Virus Inactivation, Air Microbiology. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: The study was supported by the Clinical Research Division of Sendai Medical Center, and the Japan Agency for Medical Research and Development (Grant Numbers JP….
Abstract (Originalsprache)
Ambient humidity, temperature, and ozone influence the viability of airborne viruses, but their synergistic effects are poorly understood, particularly regarding ozone with humidity/temperature changes. Therefore, we examined the inactivation of airborne influenza viruses and coronaviruses under combinations of low ambient ozone concentrations, relative humidity (RH) levels, and temperatures typical of daily life. Viral fluid was atomized in a closed chamber conditioned with different combinations of these factors. The atomized aerosol particles containing the virus were exposed to ambient air and then sampled for titration. Active virus levels in ambient air at 50%–85% RH with 15, 35, and 55 ppb ozone significantly decreased compared with those in ambient air with 0 ppb ozone, whereas those in ambient air at < 40% RH decreased only slightly, even with 100 ppb ozone. Viral gene copy numbers, assayed via quantitative real‐time polymerase chain reaction, remained similar across all conditions. Inactivation increased with higher temperatures, although not at 15°C. These findings suggest that low concentrations of ambient ozone, when combined with high humidity and temperature, effectively inactivate airborne viruses, potentially influencing viral transmission in real‐world environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinical Research Division, Virus Research Center, Sendai Medical Center, National Hospital Organization, Sendai, Japan.
- Mediair Japan Inc., Yokohama, Japan.
- Niterra Co. Ltd., Japan.
- Department of Virology III, National Institute of Infectious Diseases, Tokyo, Japan.
Förderung
- The study was supported by the Clinical Research Division of Sendai Medical Center, and the Japan Agency for Medical Research and Development (Grant Numbers JP…
Zitieren
APA
Nishimura, H., Sakata, S., Dapat, I., Segawa, M., Mizutani, Y., Imaizumi, J., Shirato, K., Ohmiya, S., Katsumi, M., & Yokoyama, T. (2025). Synergistic Inactivation of Airborne Viruses by Low‐Concentration Ozone With High Humidity and Temperature. Microbiology and Immunology. https://doi.org/10.1111/1348-0421.13204
Vancouver
Nishimura H, Sakata S, Dapat I, Segawa M, Mizutani Y, Imaizumi J, et al. Synergistic Inactivation of Airborne Viruses by Low‐Concentration Ozone With High Humidity and Temperature. Microbiology and Immunology. 2025. doi:10.1111/1348-0421.13204
BibTeX
@article{Nishimura2025,
author = {Nishimura, Hidekazu and Sakata, Soichiro and Dapat, Isolde and Segawa, Masayuki and Mizutani, Yuki and Imaizumi, Junya and Shirato, Kazuya and Ohmiya, Suguru and Katsumi, Masanori and Yokoyama, Takahiro},
title = {Synergistic Inactivation of Airborne Viruses by Low‐Concentration Ozone With High Humidity and Temperature},
journal = {Microbiology and Immunology},
year = {2025},
doi = {10.1111/1348-0421.13204}
}
EUVIMED