Rapid, Accurate 3-D Localization of Inertial Cavitation Events Using a Large Aperture, Narrowband, Receive-Capable Focused Ultrasound Array
IEEE Transactions on Ultrasonics · 2026-07 · 73 (7) · 824-836
DOI: 10.1109/tuson.2026.3702874 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, 2026-07. Verfasst von Mahmoud Komaiha und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: High-Intensity Focused Ultrasound Ablation, Imaging, Three-Dimensional. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIBIB NIH HHS, NIH.
Abstract (Originalsprache)
Accurate, real-time localization of cavitation events is critical for ensuring the safety and efficacy of histotripsy treatments. Current methods, such as 2-D passive acoustic mapping (PAM) and B-mode imaging, lack the necessary speed and spatial resolution for the high-treatment rates (> 100 Hz) of histotripsy. In this study, we present two computationally efficient, time-domain methods-trilateration acoustic cavitation emission (TRACE) and bandwidth-limited, large-aperture, active-acoustic, and spatio-temporal mapping (BLAST)-for rapid 3-D cavitation localization using a large-aperture, narrowband, and receive-capable focused ultrasound (US) array. TRACE estimates cavitation locations by measuring time-of-arrival (TOA) differences of cavitation collapse's shockwave emissions across an array, enabling direct localization with minimal computation. BLAST, a modified version of PAM, actively detects and time-windows collapse shockwave signals to improve processing efficiency. Experimental validation using synchronized optical imaging demonstrated submillimeter cavitation localization accuracy for both methods. TRACE achieved localization rates $\ge 100$ Hz with a computation time of 7 ms per pulse, while BLAST achieved rates exceeding 60 Hz. Results also confirmed a prefocal shift in cavitation center-of-mass relative to the array's geometric focus, highlighting the effect of focal pressure on bubble cloud dynamics. These findings suggest that TRACE and BLAST provide viable solutions for real-time 3-D cavitation monitoring, improving the precision and control of histotripsy treatments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- NCI NIH HHS
- NIBIB NIH HHS
- NIH
- University of Michigan, have a financial interest in HistoSonics, Inc
Zitieren
APA
Komaiha, M., Yeats, E., Hall, T. L., Xu, Z., & Sukovich, J. R. (2026). Rapid, Accurate 3-D Localization of Inertial Cavitation Events Using a Large Aperture, Narrowband, Receive-Capable Focused Ultrasound Array. IEEE Transactions on Ultrasonics, 73(7), 824-836. https://doi.org/10.1109/tuson.2026.3702874
Vancouver
Komaiha M, Yeats E, Hall TL, Xu Z, Sukovich JR. Rapid, Accurate 3-D Localization of Inertial Cavitation Events Using a Large Aperture, Narrowband, Receive-Capable Focused Ultrasound Array. IEEE Transactions on Ultrasonics. 2026;73(7):824-836. doi:10.1109/tuson.2026.3702874
BibTeX
@article{Komaiha2026,
author = {Komaiha, Mahmoud and Yeats, Ellen and Hall, Timothy L and Xu, Zhen and Sukovich, Jonathan R},
title = {Rapid, Accurate 3-D Localization of Inertial Cavitation Events Using a Large Aperture, Narrowband, Receive-Capable Focused Ultrasound Array},
journal = {IEEE Transactions on Ultrasonics},
year = {2026},
volume = {73},
number = {7},
pages = {824--836},
doi = {10.1109/tuson.2026.3702874}
}
EUVIMED