Deep-Learning-Driven High Spatial Resolution Attenuation Imaging for Ultrasound Tomography (AI-UT)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2025
DOI: 10.1109/tuffc.2025.3592578 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2025. Verfasst von Mingrui Liu und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Deep Learning, Image Processing, Computer-Assisted, Ultrasonography, Mammary. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Ultrasonic attenuation can be used to characterize tissue properties of the human breast. Both quantitative ultrasound (QUS) and ultrasound tomography (USCT) can provide attenuation estimation. However, limitations have been identified for both approaches. In QUS, the generation of attenuation maps involves separating the whole image into different data blocks. The optimal size of the data block is around 15-30 pulse lengths, which dramatically decreases the spatial resolution for attenuation imaging. In USCT, the attenuation is often estimated with a full wave inversion (FWI) method, which is affected by background noise. To achieve a high-resolution attenuation image with low variance, a deep learning (DL)-based method was proposed. In the approach, RF data from 60 angle views from the QTI Breast Acoustic CT (BACT) scanner were acquired as the input and attenuation images as the output. To improve image quality for the DL method, the spatial correlation between speed of sound (SOS) and attenuation were used as a constraint in the model. The results indicated that by including the SOS structural information, the performance of the model was improved. With a higher spatial resolution attenuation image, further segmentation of the breast can be achieved. The structural information and actual attenuation values provided by DL-generated attenuation images were validated with the values from the literature and the SOS-based segmentation map. The information provided by DL-generated attenuation images can be used as an additional biomarker for breast cancer diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- NCI NIH HHS
- National Institutes of Health
Zitieren
APA
Liu, M., Kou, Z., Wiskin, J. W., Czarnota, G. J., & Oelze, M. L. (2025). Deep-Learning-Driven High Spatial Resolution Attenuation Imaging for Ultrasound Tomography (AI-UT). IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2025.3592578
Vancouver
Liu M, Kou Z, Wiskin JW, Czarnota GJ, Oelze ML. Deep-Learning-Driven High Spatial Resolution Attenuation Imaging for Ultrasound Tomography (AI-UT). IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2025. doi:10.1109/tuffc.2025.3592578
BibTeX
@article{Liu2025,
author = {Liu, Mingrui and Kou, Zhengchang and Wiskin, James W and Czarnota, Gregory J and Oelze, Michael L},
title = {Deep-Learning-Driven High Spatial Resolution Attenuation Imaging for Ultrasound Tomography (AI-UT)},
journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2025},
doi = {10.1109/tuffc.2025.3592578}
}
EUVIMED