A 9-Fr Endovascular Therapy Transducer With an Acoustic Metamaterial Lens for Rapid Stroke Thrombectomy
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024
DOI: 10.1109/tuffc.2024.3464330 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Phuong T Vu und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Thrombectomy, Transducers, Stroke, Endovascular Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institutes of Health, Georgia Tech Institute for Electronics and Nanotechnology, a member of the National Nanotechnology Coordinated Infrastructure (NNCI), through the National Scie….
Themen: Schlaganfall
Abstract (Originalsprache)
Large vessel occlusion (LVO) stroke, in which major cerebral arteries such as the internal carotid and middle cerebral arteries supplying the brain are occluded, is the most debilitating form of acute ischemic stroke (AIS). The current gold standard treatment for LVO stroke is mechanical thrombectomy; however, initial attempts to recanalize these large, proximal arteries supplying the brain fail in up to 75% of cases, leading to repeated passes that decrease the likelihood of success and affect patient outcomes. We report the design, fabrication, and testing of a mm forward-treating ultrasound (US) transducer with an acoustic metamaterial lens to dissolve blood clots recalcitrant to first-pass mechanical thrombectomy in LVO stroke. Due to the lens with microscale features, the device was able to produce a increase in peak negative pressure (PNP) (4.3 versus 1.8 MPa) and increase in blood clot dissolution rate ( versus mg/min) with 90% mass reduction after 30 min of treatment. In this small endovascular form factor, the acoustic metamaterial lens increased the acoustic output from the transducer while minimizing the US energy delivered to the surrounding areas outside of the treatment volume.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- NIBIB NIH HHS
- National Institutes of Health
- Georgia Tech Institute for Electronics and Nanotechnology, a member of the National Nanotechnology Coordinated Infrastructure (NNCI), through the National Scie…
Zitieren
APA
Vu, P. T., Strassle Rojas, S., Ott, C. C., & Lindsey, B. D. (2024). A 9-Fr Endovascular Therapy Transducer With an Acoustic Metamaterial Lens for Rapid Stroke Thrombectomy. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2024.3464330
Vancouver
Vu PT, Strassle Rojas S, Ott CC, Lindsey BD. A 9-Fr Endovascular Therapy Transducer With an Acoustic Metamaterial Lens for Rapid Stroke Thrombectomy. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024. doi:10.1109/tuffc.2024.3464330
BibTeX
@article{Vu2024,
author = {Vu, Phuong T and Strassle Rojas, Stephan and Ott, Caroline C and Lindsey, Brooks D},
title = {A 9-Fr Endovascular Therapy Transducer With an Acoustic Metamaterial Lens for Rapid Stroke Thrombectomy},
journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2024},
doi = {10.1109/tuffc.2024.3464330}
}
EUVIMED