Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2023. Verfasst von Jian-Yu Lu und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Transducers, Retina. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NEI NIH HHS, National Institutes of Health, Unrestricted Departmental Grant from Research to Prevent Blindness.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An ultrasound concave 2-D ring array transducer was designed for applications in visual stimulation of the retina with a long-term goal to restore vision in individuals with intact neurons but suffering blindness due to retinopathies. The array was synthesized and has a frequency of 20 MHz (0.075-mm wavelengths in water), 18-mm focal length (the curvature of the concave array), 1004 elements (with a pitch of 4.0 wavelengths), and inner and outer diameters of 9 and 14 mm, respectively. Wave patterns produced with the array at the focal distance were simulated. Results show that the wave patterns obtained can achieve a full-width-at-half-maximum (FWHM) resolution of 0.147 mm that is very close to the FWHM diffraction limit (0.136 mm). In addition, a scaled experiment at a lower frequency of 2.5 MHz was performed. The result is very close to those obtained with the simulations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TransducersRetinaHumansEquipment DesignUltrasonographyPhantoms, Imaging

Förderung

  • NEI NIH HHS
  • National Institutes of Health
  • Unrestricted Departmental Grant from Research to Prevent Blindness

Zitieren

APA

Lu, J. Y., Lu, G., Thomas, B. B., Humayun, M. S., & Zhou, Q. (2023). Ultrasound Concave 2-D Ring Array for Retinal Stimulation. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2023.3321871

Vancouver

Lu JY, Lu G, Thomas BB, Humayun MS, Zhou Q. Ultrasound Concave 2-D Ring Array for Retinal Stimulation. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2023. doi:10.1109/tuffc.2023.3321871

BibTeX
@article{Lu2023,
  author = {Lu, Jian-Yu and Lu, Gengxi and Thomas, Biju B and Humayun, Mark S and Zhou, Qifa},
  title = {Ultrasound Concave 2-D Ring Array for Retinal Stimulation},
  journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
  year = {2023},
  doi = {10.1109/tuffc.2023.3321871}
}
Kostenlos starten →