EUVIMEDEUVIMED entdecken
Crossref

Integrated Fault-Tolerant Strategy of Brushless Doubly Fed Induction Generator-DC System Under Control Winding Open-Phase Fault

Yizheng Zhang, Yi Liu, Dayi Li, Omer Mohammed Elbabo Mohammed, Yan Le, Youguang Guo

IEEE Transactions on Transportation Electrification · 2026-08 · 12 (4) · 6230-6241

DOI: 10.1109/tte.2026.3684568 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Transportation Electrification, 2026-08. Verfasst von Yizheng Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Shenzhen Science and Technology Program, Guangdong Basic and Applied Basic Research Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To ensure the reliability of the brushless doubly fed induction generator-DC (BDFIG-DC) system under control winding (CW) open-phase fault, this article proposes an integrated fault-tolerant strategy encompassing fault detection, fault-tolerant control, and torque ripple suppression. First, a harmonic mathematical model is established to analyze harmonic components and torque ripple under both normal operating conditions and CW open-phase fault, and a fundamental fault-tolerant framework is proposed. Second, a fast and accurate open-phase fault detection method is proposed to promptly activate the fault-tolerant strategy. By constructing CW open-phase indexes, the proposed method can reliably distinguish the open-phase fault from normal operation and two typical fault conditions. Third, a detail fault-tolerant control scheme is developed. To ensure smooth transition to the fault-tolerant operating mode, an improved dq frame orientation is adopted. Furthermore, to enhance system reliability after fault-tolerant control activation, a harmonic-injected DC voltage is applied to the CW to suppress torque ripple induced by the three-phase diode rectifier (TDR). Finally, the effectiveness of the proposed fault detection and fault-tolerant control strategies is validated through comprehensive experimental results obtained from a 5-kVA BDFIG-DC experimental platform.

Förderung

  • Shenzhen Science and Technology Program
  • Guangdong Basic and Applied Basic Research Foundation

Zitieren

APA

Zhang, Y., Liu, Y., Li, D., Mohammed, O. M. E., Le, Y., & Guo, Y. (2026). Integrated Fault-Tolerant Strategy of Brushless Doubly Fed Induction Generator-DC System Under Control Winding Open-Phase Fault. IEEE Transactions on Transportation Electrification, 12(4), 6230-6241. https://doi.org/10.1109/tte.2026.3684568

Vancouver

Zhang Y, Liu Y, Li D, Mohammed OME, Le Y, Guo Y. Integrated Fault-Tolerant Strategy of Brushless Doubly Fed Induction Generator-DC System Under Control Winding Open-Phase Fault. IEEE Transactions on Transportation Electrification. 2026;12(4):6230-6241. doi:10.1109/tte.2026.3684568

BibTeX
@article{Zhang2026,
  author = {Zhang, Yizheng and Liu, Yi and Li, Dayi and Mohammed, Omer Mohammed Elbabo and Le, Yan and Guo, Youguang},
  title = {Integrated Fault-Tolerant Strategy of Brushless Doubly Fed Induction Generator-DC System Under Control Winding Open-Phase Fault},
  journal = {IEEE Transactions on Transportation Electrification},
  year = {2026},
  volume = {12},
  number = {4},
  pages = {6230--6241},
  doi = {10.1109/tte.2026.3684568}
}
Kostenlos starten →